ACS880-07-0590A-7
Product ID:88975
Updated: 2026/7/15

Key Features
- 1Deliver 560 kW nominal power for demanding industrial applications.
- 2Design for hazardous environments to ensure safety and reliability.
- 3Incorporate Safe Torque Off, Direct Torque Control, and PID control for precise motor control.
- 4Provide separate rectifier and inverter modules for redundancy and continuous operation.
- 5Offer IP22 protection in frame size R11 for harsh environments.
Need a quote? Enter your quantity and get pricing fast.
Qty
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product Net Weight | 580 kg 1279 lb | Product Net Depth / Length | 698 mm 27.480 in |
| Product Net Height | 2145 mm 84.449 in | Product Net Width | 830 mm 32.677 in |
| Package Level 1 Depth / Length | 1100 mm 43.307 in | Package Level 1 Height | 2385 mm 93.898 in |
| Package Level 1 Width | 1144 mm 45.039 in | Number of Phases | 3 |
| Degree of Protection | IP22 | Enclosure Type NEMA | Type1 |
| Altitude | 1000 m | Operating Humidity (RH<span style="font-size:x-small;">amb</span>) | 5 ... 95 |
| Power Factor | 0.98 | Sound dB (A) | 71 dB(A) |
| Multiple Battery Information | Lithium Coin, CR2032, 2pcs, 3V, 220mAh, 6g | Frequency (f) | 48 ... 63 Hz |
| Frame Size | R11 | Input Voltage (Uin) | 525 ... 690 V |
| Mounting Type | Cabinet-built | Communication Protocol | CAN DeviceNet EtherNet/IP MODBUS Other Bus Systems PROFIsafe PROFIBUS PROFINET IO TCP/IP |
| Number of Hardware Interfaces | Industrial Ethernet 0 Parallel 0 PROFINET 0 RS-232 0 RS-422 0 RS-485 1 Serial TTY 0 USB 1 | Includes | Control unit PC connection |
| Analog Inputs | 2 | Analog Outputs | 2 |
| Number of Digital In/Outputs | 7 / 5 | Output Current, Heavy-Duty Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">IHD</span>) | 505 A |
| Output Current, Light-Overload Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">ILD</span>) | 571 A | Output Current, Normal Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">In</span>) | 590 A |
| Output Power, Heavy-Duty Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">PHD</span>) | 500 kW | Output Power, Light-Overload Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">PLD</span>) | 560 kW |
| Output Power, Normal Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">Pn</span>) | 560 kW | Apparent Power Output | 705 kV·A |
| Standby Loss | 438 W | Temperature Rating | Maximum 40 °C Minimum 0 °C |
| Ecodesign Exemption | Energy efficiency data is not provided for this cabinet-built drive. Cabinet-built drives, with already conform modules, are excluded from the scope of the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.e). | Output Current, Heavy-Duty Use (UL) | 505 A |
| Output Current, Light-Overload Use (UL) | 571 A | Output Power, Heavy-Duty Use (UL) | 500 Hp |
| Output Power, Light-Overload Use (UL) | 600 Hp | UNSPSC | 39122001 |
| SCIP | e1aec134-b168-4e21-9c40-ee5e90c4bab4 Finland (FI) | WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Product Name | Frequency converter | Manufacturer ID | 3AUA0000154958 |
Specifications may be subject to change without notice