  • 1Deliver 150 HP and 180A for demanding industrial applications. 2、Meet international standards including CE, UL, cUL, CSA, and marine certifications. 3、Utilize direct torque control (DTC) for precise speed and torque management. 4、Extend maintenance intervals to nine years to minimize operational downtime. 5、Incorporate Safe Torque Off (STO) and other safety functions for maximum safety.
Product Details
ACS880-17-0180A-5
ABB

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Product Net Weight
705 lb
Product Net Depth / Length
26.496 in
Product Net Height
84.449 in
Product Net Width
16.929 in
Package Level 1 Depth / Length
43.307 in
Package Level 1 Height
93.898 in
Package Level 1 Width
45.039 in
Number of Phases
3
Degree of Protection
IP22
Enclosure Type NEMA
Type1
Altitude
1000 m
Operating Humidity (RH<span style="font-size:x-small;">amb</span>)
5 ... 95
Power Factor
1
Sound dB (A)
70 dB(A)
Multiple Battery Information
Lithium Coin, CR2032, 2pcs, 3V, 220mAh, 6g
Frequency (f)
48 ... 63 Hz
Frame Size
R8
Input Voltage (Uin)
380 ... 500 V
Communication Protocol
TCP/IP
Number of Hardware Interfaces
Industrial Ethernet 0 Parallel 0 PROFINET 0 RS-232 0 RS-422 0 RS-485 1 Serial TTY 0 USB 1
Includes
Control unit PC connection
Analog Inputs
2
Analog Outputs
2
Number of Digital In/Outputs
7 / 5
Output Current, Heavy-Duty Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">IHD</span>)
156 A
Output Current, Light-Overload Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">ILD</span>)
171 A
Output Current, Normal Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">In</span>)
180 A
Output Power, Heavy-Duty Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">PHD</span>)
90 kW
Output Power, Light-Overload Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">PLD</span>)
110 kW
Output Power, Normal Use (<span style="font-size:11.0pt;font-family:'Calibri',sans-serif;">Pn</span>)
110 kW
Apparent Power Output
156 kV·A
Temperature Rating
Maximum 40 °C Minimum 0 °C
Ecodesign Exemption
Energy efficiency data is not provided for the drive. The regenerative drives are exempt from the EU ecodesign requirements (Regulation EU/2019/1781, §2.3.c).
Output Current, Heavy-Duty Use (UL)
156 A
Output Current, Light-Overload Use (UL)
180 A
Output Current, Normal Use (UL)
- A
Output Power, Heavy-Duty Use (UL)
125 Hp
Output Power, Light-Overload Use (UL)
150 Hp
Output Power, Normal Use (UL)
- Hp
UNSPSC
39122001
SCIP
82D82DAE-9725-4373-865D-AA949B97DE50 Finland (FI)
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
Product Name
Frequency converter
Manufacturer ID
3AXD50000158041