DS201T B10 APR30
Product ID:76578
Updated: 2026/4/4

Key Features
- 1Safeguard circuits against overcurrent and earth fault currents. 2、Achieve high immunity to interference and electromagnetic disturbances. 3、Install easily on DIN rails with compact 85x69x35 mm dimensions. 4、Ensure reliable performance with 10 kA short-circuit capacity. 5、Meet IEC 61009-1 and EN 61009-1 safety standards.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Standards | IEC 61009-1 IEC 61009-2-1 EN 61009-1 EN 61009-2-1 EN 45545 | Tripping Characteristic | B |
| Type of Residual Current | Type APR | Application | Traction |
| Rated Operational Voltage | acc. to IEC 60898-1 230 V | Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
| Test Voltage (Ut) | 170 ... 264 V | Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Dielectric Test Voltage | 2 kV | Input Voltage Type | AC |
| Rated Current (In) | 10 A | Rated Residual Current | 30 mA |
| Rated Short-Circuit Capacity | 6 kA | Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 10 kA |
| Rated Residual Breaking Capacity (IΔm) | EN 61009-1 6000 A IEC 61009-1 6000 A | Rated Service Short-Circuit Breaking Capacity (Ics) | 7.5 kA |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 6 kA | Maximum Surge Current | 3 kA |
| Rated Frequency (f) | 50 ⦠60 Hz | Power Loss | Average per Pole 1.2 W Phase Pole 1.8 W Neutral Pole 0.5 W Total 2.3 W |
| Power Supply Connection | Arbitrary | Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 | Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 20000 cycle | Number of Protected Poles | 1 |
| Number of Poles | 2 | Number of Modular Spacings per DIN Rail | 2 |
| Fault Indication | Blue flag on toggle | Operating Characteristic | Instantaneous (APR High Immunity) |
| Overvoltage Category | III | Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m | Accessory Type | Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device |
| Actuator Type | Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions | Earthing Switch Type | Short-Time Delayed |
| Housing Type | Insulation group I - II, RAL 7035 | Mounting Type | DIN-Rail |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal | Options Provided | Suitable for traction applications |
| Mounting Position | Any | Accessories Available | Yes |
| Surge Immunity acc. to IEC 61000-4-5 | 3000 A | Number of Batteries | 0 |
| Connecting Capacity | Busbar 10 ... 10 mm² Stranded 0.75 ... 25 mm² Flexible with Ferrule 0.75 ... 16 mm² Flexible 0.75 ... 16 mm² | Rated Cross-Section | 1 - Solid-Core 0.75 ⦠25 mm² 4 - Multi-Wired 0.75 ⦠16 mm² |
| Wire Stripping Length | 12 mm | Terminal Type | Screw Terminals |
| Ambient Air Temperature | Operation -25 ⦠55 °C | Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | IP20 IP40 | Pollution Degree | 2 |
| Environmental Conditions | 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % | Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 ⦠150 ⦠5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms | Environmental Information | 2CSC422002K2701 |
| Width in Number of Modular Spacings | 2 | Product Net Width | 35 mm |
| Product Net Height | 85 mm | Product Net Depth / Length | 69 mm |
| Product Net Weight | 182 g | Built-In Depth (t2) | 35 mm |
| ETIM 8 | EC000905 - Earth leakage circuit breaker | ETIM 9 | EC000905 - Earth leakage circuit breaker |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | WEEE B2C / B2B | Business To Consumer |
| CN8 | 85363010 | UNSPSC | 39121601 |
| eClass | V11.0 : 27142207 | IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) |
| Object Classification Code | F | Manufacturer ID | 2CSR255488R1105 |
Specifications may be subject to change without notice