Key Features
- 1Enhance safety by protecting against AC and pulsating DC ground faults. 2、Ensure compliance with IEC/EN 61008 and UL 1053 international standards. 3、Detect residual currents with high sensitivity down to 500 mA. 4、Achieve long service life through 10,000 electrical and 20,000 mechanical cycles. 5、Save panel space with a compact design for efficient DIN rail mounting.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Standards | IEC 61008 | Type of Residual Current | Type AC |
| Rated Voltage (Ur) | 230 V | Rated Operational Voltage | 230 V |
| Rated Insulation Voltage (Ui) | 500 V | Test Voltage (Ut) | 110-254 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV | Input Voltage Type | AC |
| Rated Current (In) | 100 A | Rated Residual Current | 500 mA |
| Rated Conditional Short-Circuit Current (Inc) | 10 kA | Maximum Surge Current | 0.25 kA |
| Leakage Current Type | AC | Frequency (f) | 50/60 Hz |
| Rated Frequency (f) | 50 ⦠60 Hz | Power Loss | at Rated Operating Conditions per Pole 6.5 W |
| Power Supply Connection | Arbitrary | Electrical Endurance | 10000 cycle |
| Number of Poles | 2 | Number of Modular Spacings per DIN Rail | 2 |
| Operating Characteristic | Instantaneous | Tightening Torque | 2.8 N·m |
| Accessory Type | Auxiliary contact Signal / auxiliary contact Shunt trip Auto re-closing units Motor operating device Overvoltage release Undervoltage release | Mounting Type | DIN-Rail |
| Options Provided | None | Mounting Position | Any |
| Accessories Available | Yes | Connecting Capacity | Busbar 10 mm² Rigid 35 ... 35 mm² Flexible 35 ... 35 mm² |
| Rated Cross-Section | 4 - Multi-Wired 0...35 mm² 1 - Solid-Core 35...35 mm² | Wire Stripping Length | Top 12.7 mm Bottom 14.9 mm |
| Terminal Type | Screw Terminals | Ambient Air Temperature | Operation -25 ... 55 °C Storage -40 ... 70 °C |
| Degree of Protection | IP2X | Pollution Degree | 2 |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 ⦠150 ⦠5 Hz | Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
| Environmental Information | Refer to RoHS | Maximum Operating Voltage UL/CSA | 277 V AC |
| Short-Circuit Current Rating (SCCR) | 500 mA | Width in Number of Modular Spacings | 2 |
| Product Net Width | 35 mm | Product Net Height | 85 mm |
| Product Net Depth / Length | 69 mm | Product Net Weight | 200 g |
| Built-In Depth (t2) | 69 mm | ETIM 8 | EC000003 - Residual current circuit breaker (RCCB) |
| ETIM 9 | EC000003 - Residual current circuit breaker (RCCB) | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer | CN8 | 85363030 |
| eClass | V11.0 : 27142201 | IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) |
| Object Classification Code | F | Manufacturer ID | 2CSF202005R4900 |
Specifications may be subject to change without notice