Key Features

  • 1Ensure easy operation with clear switch position indication. 2、Disconnect motors safely and efficiently with the disconnect function. 3、Adjust current settings from 0.25 to 0.4A for precise overload protection. 4、Save installation space with compact 90x45x86.75 mm dimensions. 5、Protect against solid objects with an IP20 enclosure rating.
Product Details
MS132-0.4
ABB

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Product Net Width
45 mm
Product Net Height
90 mm
Product Net Depth / Length
86.75 mm
Product Net Weight
0.215 kg
Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 100 kA (250 V DC) 3 Poles in Series 10 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)
5 A
Setting Range
0.25 ... 0.40 A
Rated Operational Power AC-3 (Pe)
(400 V) Three Phase 0.09 kW
Rated Operational Power AC-3e (Pe)
(400 V) Three Phase 0.09 kW
Rated Operational Voltage
Main Circuit 690 V AC Main Circuit 250 V DC
Rated Operational Current (Ie)
0.4 A
Rated Operational Current AC-3 (Ie)
0.4 A
Rated Operational Current AC-3e (Ie)
0.4 A
Rated Operational Current DC-5 (Ie)
0.4 A
Rated Frequency (f)
Main Circuit 50 Hz Main Circuit 60 Hz
Operating Frequency (fsw)
0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 0.6 ... 1.7 W
Number of Poles
3
Conventional Free-air Thermal Current (Ith)
Main Circuit 0.4 A
Degree of Protection
Housing IP20 Main Circuit Terminals IP10
Pollution Degree
3
Electrical Durability
50000 cycle
Mechanical Durability
100000 cycle
Terminal Type
Screw Terminals
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm²
Tightening Torque
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length
Main Circuit 9 mm
Recommended Screw Driver
Pozidriv 2
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm
Actuator Type
Rotary Handle
Contact Position Indication
ON / OFF / TRIP
Standards
IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
Remarks
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Short-Circuit Current Rating (SCCR)
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Full Load Amps Motor Use
(200 V AC) Three Phase 0.4 A (208 V AC) Three Phase 0.4 A (220 ... 240 V AC) Three Phase 0.4 A (440 ... 480 V AC) Three Phase 0.4 A (550 ... 600 V AC) Three Phase 0.4 A
Locked Rotor Amps
(200 V AC) Three Phase 2.4 A (208 V AC) Three Phase 2.4 A (220 ... 240 V AC) Three Phase 2.4 A (440 ... 480 V AC) Three Phase 2.4 A (550 ... 600 V AC) Three Phase 2.4 A
General Use Rating UL/CSA
(600 V AC) 0.4 A
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA
Main Circuit 10 ... 12 in·lb
Ambient Air Temperature
Around the Enclosure 0 ... +40 °C Operation -25 ... +70 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations
5g 3 ... 150 Hz
Object Classification Code
F
ETIM 4
EC000074 - Motor protective circuit-breaker
ETIM 5
EC000074 - Motor protective circuit-breaker
ETIM 6
EC000074 - Motor protection circuit-breaker
ETIM 7
EC000074 - Motor protection circuit-breaker
ETIM 8
EC000074 - Motor protection circuit-breaker
eClass
V11.0 : 27370401
UNSPSC
39121521
IDEA Granular Category Code (IGCC)
4731 >> Manual Starters
E-Number (Finland)
3705987
E-Number (Norway)
4364072
E-Number (Sweden)
3112119
Manufacturer ID
1SAM350000R1003