OS1250B04F
Product ID:75394
Updated: 2026/4/3

Key Features
- 1Engineer for extreme conditions to ensure reliable motor protection. 2、Simplify installation and maintenance with adjustable shafts and snap-on accessories. 3、Prevent opening while the switch is on with interlocking fuse covers to reduce electric shock risk. 4、Handle up to 1250 A for demanding industrial applications. 5、Meet IEC 60947-3 technical specifications for safety and performance.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Pollution Degree | 3 | Product Net Width | 294 mm |
| Product Net Height | 539 mm | Product Net Depth / Length | 356 mm |
| Product Net Weight | 36.5 kg | Conventional Free-air Thermal Current (Ith) | Π= 40 °C 1250 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 1000 A | Fourth Pole Type | Switched - Fusible Pole |
| Fuse Size | D1 | Fuse System | British Standard |
| Handle Type | Handle and shaft not included | Mounting Type | Base mounting |
| Number of Poles | 4 | Operating Mode | Front Operated |
| Pollution Degree | 3 | Position of Line Terminals | Top In - Bottom Out Bottom In - Top Out |
| Power Loss | at Rated Operating Conditions per Pole 75 W | Rated Conditional Short-Circuit Current (Inc) | (690 V) 80 kA |
| Rated Current (In) | Main Circuit 1250 A | Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V | Rated Operational Current AC-21A (Ie) | (690 V) 1250 A (690 V) 380415V;1250 A (690 V) 500V;1250 A |
| Rated Operational Current AC-21B (Ie) | (500 V) 1250 A (690 V) 1250 A | Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 1250 A |
| Rated Operational Current AC-22B (Ie) | (500 V) 1250 A (690 V) 1250 A | Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 1000 A |
| Rated Operational Current AC-23B (Ie) | (500 V) 1000 A (690 V) 1000 A | Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 315 kW (400 V) 560 kW (415 V) 560 kW (500 V) 710 kW (690 V) 1000 kW |
| Rated Operational Voltage | Main Circuit 690 V AC | Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 40 kiloampere rms |
| Standards | IEC 60947-3 | Switches Operating Mechanism | 04 (Left Side) |
| Terminal Type | Lug terminals | Terminal Width | 50 mm |
| Tightening Torque | 50 ... 75 N·m | Tightening Torque | 50 ... 75 N·m |
| Object Classification Code | Q | ETIM 8 | EC001040 - Fuse switch disconnector |
| ETIM 9 | EC001040 - Fuse switch disconnector | UNSPSC | 39122233 |
| IDEA Granular Category Code (IGCC) | 5291 >> Fuse switch disconnector | eClass | V11.1 : 27371401 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) | Manufacturer ID | 1SCA105257R1001 |
Specifications may be subject to change without notice