OT1000E04W4P

Product ID:86872
Updated: 2026/4/4
ABB OT1000E04W4P

Key Features

  • 1Optimize panel space with a compact, double-sided spring design. 2、Deliver high performance with full AC-23A ratings up to 1000A. 3、Enhance safety using inbuilt features and IP65 protected handles. 4、Simplify installation via adjustable feet for top or side mounting. 5、Ensure long-term reliability with 20,000 mechanical operation cycles.
Product Details
OT1000E04W4P
ABB

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Degree of Protection
Front IP00
Environmental Information
1SCC301233D0201
Pollution Degree
3
Product Net Width
594.5 mm
Product Net Height
306 mm
Product Net Depth / Length
167 mm
Product Net Weight
23.1 kg
Conventional Free-air Thermal Current (Ith)
Θ = 40 °C 1000 A
Conventional Thermal Current (Ithe)
Fully Enclosed 1000 A
Degree of Protection
Front IP00
Distance Between Phases
Phase distance 140 mm
Fourth Pole Position
Right Side
Fourth Pole Type
Switched - Simultaneous Function
Handle Color
Black
Handle Type
Handle and shaft included
Lock Type
Yes
Mechanical Durability
6000
Mounting Type
Base mounting
Number of Poles
4P
Operating Mode
Front operated
Pollution Degree
3
Position of Line Terminals
Top In - Bottom Out Bottom In - Top Out
Power Loss
at Rated Operating Conditions per Pole 19 W
Rated Conditional Short-Circuit Current (Inc)
(1250 A fuse, 415 V) 80 kA (1250 A fuse, 500 V) 100 kA
Rated Impulse Withstand Voltage (Uimp)
12 kV
Rated Insulation Voltage (Ui)
acc. to IEC/EN 60664-1 1000 V
Rated Operational Current AC-21A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Current AC-22A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Current AC-23A (Ie)
(380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A
Rated Operational Power AC-23A (Pe)
(400 ... 415 V) 560 kW (500 V) 710 kW (690 V) 1000 kW
Rated Operational Voltage
Main Circuit 1000 V
Rated Short-Circuit Making Capacity (Icm)
(690 V) 92 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 50 kA
Special Functions
Wide phase distance 140
Standards
IEC 60947-3
Switches Operating Mechanism
Mechanism at the End of the Switch 04 (Left Side)
Terminal Type
Lug terminals
Terminal Width
50 mm
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Tightening Torque
acc. IEC 60947-1 50 … 75 N·m
Object Classification Code
Q
ETIM 8
EC000216 - Switch disconnector
ETIM 9
EC000216 - Switch disconnector (low voltage)
eClass
V11.1 : 27371403
WEEE Category
4. Large Equipment (Any External Dimension More Than 50 cm)
E-Number (Finland)
3660832
Manufacturer ID
1SCA100762R1001

Specifications may be subject to change without notice