OT160E04C
Product ID:88921
Updated: 2026/4/3

Key Features
- 1Handle up to 160A current for robust power control. 2、Install easily in small enclosures with a modular, space-saving design. 3、Ensure operator safety with manual emergency operation and padlocking. 4、Apply across machinery, PV systems, and motor control centers. 5、Meet IEC, UL, and CSA standards for guaranteed compliance and durability.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Degree of Protection | Front IP20 | Environmental Information | 1SCC303050D0201 |
| Pollution Degree | 3 | Product Net Width | 205 mm 8.07 in |
| Product Net Height | 150 mm 5.91 in | Product Net Depth / Length | 160 mm 6.3 in |
| Product Net Weight | 3.6 kg 7.94 lb | Conventional Free-air Thermal Current (Ith) | Π= 40 °C 160 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 160 A | Degree of Protection | Front IP20 |
| Distance Between Phases | Standard | Fourth Pole Position | Right Side |
| Fourth Pole Type | Switched - Simultaneous Function | Handle Color | Black |
| Handle Type | Handle and shaft not included | Mounting Type | Base mounting |
| Number of Poles | 4P | Operating Mode | Front operated |
| Pollution Degree | 3 | Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
| Power Loss | at Rated Operating Conditions per Pole 2.4 W | Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V | Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A | Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 160 A (500 V) 160 A (690 V) 160 A |
| Rated Operational Current AC-31B (Ie) | (380 ... 415 V) 160 A | Rated Operational Current AC-33B (Ie) | (380 ... 415 V) 160 A |
| Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 90 kW (500 V) 110 kW (690 V) 160 kW | Rated Operational Voltage | Main Circuit 1000 V |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 8 kiloampere rms | Switches Operating Mechanism | Mechanism at the End of the Switch 04 (Left Side) |
| Terminal Type | Screw Terminals | Terminal Width | 20 mm |
| Tightening Torque | acc. IEC 60947-1 15 ... 22 N·m | Transition Type | Open |
| Ampere Rating | 160 A | Tightening Torque | acc. IEC 60947-1 15 ... 22 N·m |
| Object Classification Code | Q | ETIM 8 | EC000216 - Switch disconnector |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) | eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | Manufacturer ID | 1SCA022775R6770 |
Specifications may be subject to change without notice