Key Features
- 1Provide reliable circuit protection with advanced tripping features. 2、Construct with rigid acid-proof AISI316L steel for durability. 3、Install easily in compact spaces across various settings. 4、Enhance safety with interlocks, pressure relief, and padlockable handles. 5、Deploy versatile OT400ESUR6TZ breaker for indoor and outdoor use.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Degree of Protection | acc. to IEC 60529 IP65 | Pollution Degree | 3 |
| Product Net Width | 800 mm | Product Net Height | 800 mm |
| Product Net Depth / Length | 230 mm | Product Net Weight | 50.14 kg |
| Cable Entry Position | Bottom/Bottom | Cable Outlets Per Side | Blank / 8xring-flange+ø25.5mm |
| Connecting Capacity Main Circuit | Hole Diameter 10 mm Screw Clamp / PE Terminal 8pc,25 ... 120 mm² | Conventional Thermal Current (Ithe) | Fully Enclosed 400 A |
| Degree of Protection | acc. to IEC 60529 IP65 | Enclosure Material | Stainless steel |
| Handle Color | Stainless Steel | Handle Type | Pistol handle |
| Impact Resistance Rating | Housing IK09 | Maximum Mounted Auxiliary Contacts | 4 NO, 2 NC |
| Mounted Auxiliary Contacts | 4 NO, 2 NC | Number of Auxiliary Contacts NC | 2 |
| Number of Auxiliary Contacts NO | 4 | Number of Poles | 6P |
| Pollution Degree | 3 | Power Loss | at Rated Operating Conditions per Pole 10 W |
| Rated Conditional Short-Circuit Current (Inc) | 61.5 kA | Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1000 V | Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A | Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 220 kW (500 V) 280 kW (690 V) 355 kW |
| Rated Operational Voltage | Main Circuit 1000 V | Rated Short-Circuit Making Capacity (Icm) | (1000 V AC) 65 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 15 kA | Recommended Screw Driver | Main Circuit M10 |
| Special Functions | EMC | Standards | IEC 60947-1, -3 |
| Tightening Torque | Main Circuit 44 N·m | Recommended Screw Driver | Main Circuit M10 |
| Tightening Torque | Main Circuit 44 N·m | Object Classification Code | Q |
| ETIM 8 | EC000216 - Switch disconnector | ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| UNSPSC | 39122205 | IDEA Granular Category Code (IGCC) | 5166 >> Safety switch |
| eClass | V11.1 : 27371403 | WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Manufacturer ID | 1SCA102335R1001 |