OT630KFCC3B
Product ID:73683
Updated: 2026/7/14

Key Features
- 1Withstand outdoor conditions with UV protection and an IP65 rating.
- 2Secure the installation using a handle that accommodates three padlocks.
- 3Ensure safe operation with an optionally defeatable interlocked cover.
- 4Handle high-power loads up to 570A and 400kW reliably.
- 5Rely on a durable rigid glass reinforced polycarbonate enclosure.
Need a quote? Enter your quantity and get pricing fast.
Qty
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Degree of Protection | acc. to IEC 60529 IP65 | Pollution Degree | 3 |
| Product Net Width | 560 mm | Product Net Height | 760 mm |
| Product Net Depth / Length | 250 mm | Product Net Weight | 18.33 kg |
| Cable Entry Position | Top/Bottom | Cable Outlets Per Side | 2xII-flange / 2xII-flange |
| Connecting Capacity Main Circuit | Hole Diameter 12 mm Screw Clamp / PE Terminal 4pc,25 ... 120 mm² | Conventional Thermal Current (Ithe) | Fully Enclosed 570 A |
| Degree of Protection | acc. to IEC 60529 IP65 | Enclosure Material | Plastic |
| Handle Color | Black | Handle Type | Pistol handle |
| Impact Resistance Rating | Housing IK08 | Maximum Mounted Auxiliary Contacts | 2 NO, 2 NC |
| Mounted Auxiliary Contacts | 0 NO, 0 NC | Neutral Type | Detachable neutral |
| Number of Auxiliary Contacts NC | 0 | Number of Auxiliary Contacts NO | 0 |
| Number of Poles | 3 | Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out | Position of Neutral Terminals | Top In - Bottom Out |
| Position of PE Terminals | Top In - Bottom Out | Power Loss | at Rated Operating Conditions per Pole 25 W |
| Rated Conditional Short-Circuit Current (Inc) | 90 kA | Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1000 V |
| Rated Operational Current AC-21A (Ie) | (500 V) 570 A (380 ... 415 V) 570 A (690 V) 570 A | Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 570 A (690 V) 570 A |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 570 A (500 V) 570 A (690 V) 570 A | Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 315 kW (500 V) 400 kW (690 V) 560 kW |
| Rated Operational Voltage | Main Circuit 1000 V | Rated Short-Circuit Making Capacity (Icm) | (1000 V AC) 80 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 20 kA | Recommended Screw Driver | Main Circuit M12 |
| Standards | IEC 60947-1, -3 | Tightening Torque | Main Circuit 75 N·m |
| Recommended Screw Driver | Main Circuit M12 | Tightening Torque | Main Circuit 75 N·m |
| Object Classification Code | Q | ETIM 8 | EC000216 - Switch disconnector |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) | UNSPSC | 39122205 |
| IDEA Granular Category Code (IGCC) | 5166 >> Safety switch | eClass | V11.1 : 27371403 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) | Manufacturer ID | 1SCA022278R3980 |