OTM1000E4CM230C
Product ID:83655
Updated: 2026/4/4

Key Features
- 1Ensure reliable operation with a high-rated insulation voltage of 1000 V. 2、Handle robust loads with a conventional free-air thermal current of 1000 A at 40°C. 3、Access easy manual operation via the mechanism at the switch end. 4、Simplify installation using the included handle and bolt kit with nut and washers. 5、Mount securely in various industrial applications with a base design for pollution degree 3.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Degree of Protection | Front IP20 | Environmental Information | 1SCC303036D0202 |
| Pollution Degree | 3 | Product Net Width | 587 mm 23.11 in |
| Product Net Height | 306 mm 12.05 in | Product Net Depth / Length | 297 mm 11.69 in |
| Product Net Weight | 62 kg 136.69 lb | Conventional Free-air Thermal Current (Ith) | Π= 40 °C 1000 A |
| Degree of Protection | Front IP20 | Distance Between Phases | Standard |
| Fourth Pole Position | Right Side | Fourth Pole Type | Switched - Simultaneous Function |
| Handle Color | Black | Handle Type | Direct mounted handle |
| Motor Operational Voltage | 220 ... 240 V AC | Mounting Type | Base mounting |
| Number of Poles | 4P | Operating Mode | Front operated |
| Pollution Degree | 3 | Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out |
| Power Loss | at Rated Operating Conditions per Pole 19 W | Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V | Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A | Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 1000 A (500 V) 1000 A (690 V) 1000 A |
| Rated Operational Current AC-31B (Ie) | (380 ... 415 V) 1000 A | Rated Operational Current AC-33B (Ie) | (380 ... 415 V) 1000 A |
| Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 560 kW (500 V) 710 kW (690 V) 1000 kW | Rated Operational Voltage | Main Circuit 1000 V |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kiloampere rms | Switches Operating Mechanism | Mechanism at the End of the Switch |
| Terminal Type | Screw Terminals | Tightening Torque | acc. IEC 60947-1 50 ... 75 N·m |
| Transition Type | Open | Tightening Torque | acc. IEC 60947-1 50 ... 75 N·m |
| Object Classification Code | Q | ETIM 8 | EC000216 - Switch disconnector |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) | eClass | V11.1 : 27371403 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) | E-Number (Finland) | 3641776 |
| Manufacturer ID | 1SCA112703R1001 |
Specifications may be subject to change without notice