- 1Deliver high performance for demanding applications in a compact solution. 2、Enhance safety with comprehensive inbuilt features and manual emergency operation. 3、Ensure operational flexibility with an included manual operation handle. 4、Secure connections using the provided terminal bolt kit for control circuits. 5、Rely on robust construction weighing 26 kg with dimensions of 506.5x372x153 mm.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Degree of Protection | Front IP00 | Pollution Degree | 3 |
| Product Net Width | 506.5 mm | Product Net Height | 372 mm |
| Product Net Depth / Length | 153 mm | Product Net Weight | 26 kg |
| Conventional Free-air Thermal Current (Ith) | Π= 40 °C 1600 A | Conventional Thermal Current (Ithe) | Fully Enclosed 1600 A |
| Degree of Protection | Front IP00 | Distance Between Phases | Standard |
| Handle Color | Black | Handle Type | Direct mounted handle |
| Lock Type | Yes | Mechanical Durability | 6000 |
| Motor Operational Voltage | 220 ... 240 V AC | Mounting Type | Base mounting |
| Number of Poles | 3P | Operating Mode | Front operated |
| Pollution Degree | 3 | Position of Line Terminals | Top In - Bottom Out |
| Power Loss | at Rated Operating Conditions per Pole 48 W | Rated Conditional Short-Circuit Current (Inc) | (1250 A fuse, 415 V) 80 kA (1250 A fuse, 500 V) 100 kA |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV | Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 1000 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 1600 A (500 V) 1600 A (690 V) 1600 A (1000 V AC) 1600 A | Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 1600 A (500 V) 1600 A (690 V) 1600 A |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 1250 A (500 V) 1250 A (690 V) 1250 A | Rated Operational Power AC-23A (Pe) | (400 ... 415 V) 710 kW (500 V) 900 kW (690 V) 1200 kW |
| Rated Operational Voltage | Main Circuit 1000 V | Rated Short-Circuit Making Capacity (Icm) | (690 V) 110 kA |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA | Special Functions | No |
| Standards | IEC 60947-3 | Switches Operating Mechanism | Mechanism at the End of the Switch |
| Terminal Type | Lug terminals | Tightening Torque | acc. IEC 60947-1 50 ⦠75 N·m |
| Tightening Torque | acc. IEC 60947-1 50 ⦠75 N·m | Object Classification Code | Q |
| ETIM 8 | EC000216 - Switch disconnector | ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| eClass | V11.1 : 27371403 | WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| Manufacturer ID | 1SCA115366R1001 |