Key Features
- 1Ensure seamless transitions with a reliable motorized mechanism. 2、Designed for efficient operations with 1000V rated insulation voltage. 3、Operate conveniently using the direct mounted handle. 4、Enhance safety with clear and visible transition indicators. 5、Meet environmental standards with RoHS and REACH compliance.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Degree of Protection | Front IP20 | Environmental Information | 1SCC303036D0202 |
| Pollution Degree | 3 | Product Net Width | 367 mm 14.45 in |
| Product Net Height | 185 mm 7.28 in | Product Net Depth / Length | 235 mm 9.25 in |
| Product Net Weight | 9.4 kg 20.72 lb | Conventional Free-air Thermal Current (Ith) | Π= 40 °C 400 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 400 A | Degree of Protection | Front IP20 |
| Distance Between Phases | Standard | Fourth Pole Position | Right Side |
| Fourth Pole Type | Switched - Simultaneous Function | Handle Color | Black |
| Handle Type | Direct mounted handle | Motor Operational Voltage | 220 ... 240 V AC |
| Mounting Type | Base mounting | Number of Poles | 4P |
| Operating Mode | Front operated | Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out, Bottom In - Top Out | Power Loss | at Rated Operating Conditions per Pole 10 W |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV | Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A | Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A |
| Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 400 A (500 V) 400 A (690 V) 400 A | Rated Operational Current AC-31B (Ie) | (380 ... 415 V) 400 A |
| Rated Operational Current AC-33B (Ie) | (380 ... 415 V) 400 A | Rated Operational Power AC-23A (Pe) | (380 ... 415 V) 220 kW (500 V) 280 kW (690 V) 400 kW |
| Rated Operational Voltage | Main Circuit 1000 V | Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 15 kiloampere rms |
| Switches Operating Mechanism | Mechanism at the End of the Switch | Terminal Type | Screw Terminals |
| Tightening Torque | acc. IEC 60947-1 30 ... 44 N·m | Transition Type | Open |
| Tightening Torque | acc. IEC 60947-1 30 ... 44 N·m | Object Classification Code | Q |
| ETIM 8 | EC000216 - Switch disconnector | ETIM 9 | EC000216 - Switch disconnector (low voltage) |
| eClass | V11.1 : 27371403 | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| E-Number (Finland) | 3641756 | Manufacturer ID | 1SCA022847R3250 |
Specifications may be subject to change without notice