OTM40F4M230V
Product ID:83572
Updated: 2026/4/3

Key Features
- 1Ensure reliable operations with high-performance switch-disconnectors. 2、Maximize panel space using a compact and efficient design. 3、Choose between manual or motorized operation for flexibility. 4、Deploy confidently with 230V rating for various applications. 5、Meet strict safety standards including IEC and UL certifications.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Degree of Protection | Front IP20 | Pollution Degree | 3 |
| Product Net Width | 186.5 mm | Product Net Height | 100 mm |
| Product Net Depth / Length | 116 mm | Product Net Weight | 1 kg |
| Cable Cross-Section | Cu 0.75 ... 10 mm² | Conventional Free-air Thermal Current (Ith) | Π= 40 °C 40 A |
| Conventional Thermal Current (Ithe) | Fully Enclosed 40 A | Degree of Protection | Front IP20 |
| Distance Between Phases | Standard | Fourth Pole Position | Right Side |
| Fourth Pole Type | Switched - Simultaneous Function | Handle Color | Black |
| Handle Type | Direct mounted handle | Lock Type | Yes |
| Mechanical Durability | 20000 | Motor Operational Voltage | 110 ... 240 V AC/DC |
| Mounting Type | Base mounting | Number of Poles | 4P |
| Operating Mode | Front operated | Pollution Degree | 3 |
| Position of Line Terminals | Top In - Bottom Out | Power Loss | at Rated Operating Conditions per Pole 1.6 W |
| Rated Conditional Short-Circuit Current (Inc) | (125 A fuse, 415 V) 50 kA (125 A fuse, 690 V) 18 kA (63 A fuse, 690 V) 50 kA | Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 750 V | Rated Operational Current AC-21A (Ie) | (380 ... 415 V) 40 A (500 V) 40 A (690 V) 40 A |
| Rated Operational Current AC-22A (Ie) | (380 ... 415 V) 40 A (500 V) 40 A (690 V) 40 A | Rated Operational Current AC-23A (Ie) | (380 ... 415 V) 23 A (500 V) 23 A (690 V) 12 A |
| Rated Operational Power AC-23A (Pe) | (220 ... 240 V) 5.5 kW (400 ... 415 V) 11 kW (500 V) 11 kW (690 V) 11 kW | Rated Operational Voltage | Main Circuit 750 V |
| Rated Short-Circuit Making Capacity (Icm) | (690 V) 0.71 kA | Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 0.5 kA |
| Special Functions | No | Standards | IEC 60947-3 |
| Switches Operating Mechanism | Mechanism at the End of the Switch | Terminal Type | Screw Terminals |
| Tightening Torque | acc. IEC 60947-1 0.8 N·m | Tightening Torque | acc. IEC 60947-1 0.8 N·m |
| Object Classification Code | Q | ETIM 8 | EC000216 - Switch disconnector |
| ETIM 9 | EC000216 - Switch disconnector (low voltage) | eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) | Manufacturer ID | 1SCA122977R1001 |
Specifications may be subject to change without notice