PST210-690-70T

Product ID:72852
Updated: 2026/4/3
ABB PST210-690-70T

Key Features

  • 1Manage motor start/stop efficiently with adjustable timing. 2、Optimize pump control with excellent torque characteristics. 3、Protect your motor with dual overload and adaptable underload protection. 4、Integrate seamlessly via Profibus, Modbus, Devicenet, or CANopen. 5、Reduce wiring and installation time with a compact, built-in bypass contactor.
Product Details
PST210-690-70T
ABB

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Product Net Width
360 mm
Product Net Height
420 mm
Product Net Depth / Length
270 mm
Product Net Weight
21.5 kg
Rated Operational Voltage
Main Circuit 400 ... 690 V AC
Rated Control Supply Voltage (Us)
100 ... 250 V AC
Rated Control Circuit Voltage (Uc)
DC Operation 24 V
Rated Frequency (f)
50/60 Hz Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)
(400 V) 110 kW (500 V) 132 kW (690 V) 184 kW
Rated Operational Current - In-Line Connection (Ie)
210 A
Rated Operational Power - Inside Delta Connection
at 400 V 184 kW at 500 V 250 kW at 690 V 315 kW
Rated Operational Current - Inside Delta Connection
360 A
Service Factor Percentage
115 %
Overload Protection
Build-in electronic overload protection
Integrated Electronic Overload
Yes
Adjustable Rated Motor Current Ie
30 ... 115 %
Starting Capacity at Maximum Rated Current Ie
3xIe for 15s
Ramp Time
0 ... 120 second [unit of time] 1 ... 120 second [unit of time]
Initial Voltage During Start
30 ... 70 %
Step Down Voltage Special Ramp
100 ... 30 %
Current Limit Function
1.5 ... 7xIe
Switch for Inside Delta Connection
Yes
Run Signal Relay
Yes
By-pass Signal Relay
Yes
Fault Signal Relay
Yes
Overload Signal Relay
Yes
Analog Outputs
0…10 volts 0…20 mA 4…20 mA
Signal Indication Ready to Start/Standby ON (LED)
Green
Signal Indication Protection (LED)
Yellow
Signal Indication Fault (LED)
Red
Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time
30
Communication
FiledBusPlug(Standard)
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type
Main Circuit: Bars
Connecting Capacity Main Circuit
Hole Diameter 10.2 mm Width and Thickness 20x5 mm
Connecting Capacity Control Circuit
Rigid 1 x 2.5 mm² Rigid 2 x 1.5 mm²
Connecting Capacity Supply Circuit
Rigid 1 x 2.5 mm²
Tightening Torque
Control Circuit 0.5 N·m Main Circuit 28 N·m Supply Circuit 0.5 N·m
Product Main Type
PST210
Ambient Air Temperature
Operation 0 ... +50 °C Storage -25 ... +70 °C
Object Classification Code
Q
ETIM 7
EC000640 - Soft starter
ETIM 8
EC000640 - Soft starter
ETIM 9
EC000640 - Soft starter
eClass
V11.0 : 27370907
Manufacturer ID
1SFA895012R7020