TF42-10B

Product ID:83196
Updated: 2026/4/3
ABB TF42-10B

Key Features

  • 1Provide reliable overload protection with trip class 10. 2、Detect phase loss sensitivity for comprehensive motor safety. 3、Adjust current settings for customizable overload protection. 4、Select automatic or manual reset for operational flexibility. 5、Ensure versatility in three- and single-phase applications.
Product Details
TF42-10B
ABB

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Product Net Width
45 mm
Product Net Height
88.3 mm
Product Net Depth / Length
70.5 mm
Product Net Weight
0.13 kg
Setting Range
7.6 ... 10 A
Rated Operational Voltage
Auxiliary Circuit 600 V AC/DC Main Circuit 690 V AC
Rated Operational Current (Ie)
10 A
Rated Frequency (f)
Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Number of Poles
3P
Number of Auxiliary Contacts NC
1
Number of Auxiliary Contacts NO
1
Number of Protected Poles
3
Conventional Free-air Thermal Current (Ith)
Auxiliary Circuit NC 6 A Auxiliary Circuit NO 4 A Main Circuit 0 A
Rated Operational Current AC-15 (Ie)
(120 V) NC 3 A (120 V) NO 0.75 A (240 V) NC 3 A (240 V) NO 0.75 A (400 V) NC 0.75 A (400 V) NO 0.75 A (500 V) NC 0.75 A (500 V) NO 0.75 A
Rated Operational Current DC-13 (Ie)
(125 V) NC 0.55 A (125 V) NO 0.55 A (24 V) NC 1.25 A (24 V) NO 1.25 A (250 V) NC 0.27 A (250 V) NO 0.27 A (500 V) NC 0.15 A (500 V) NO 0.15 A (60 V) NC 0.55 A (60 V) NO 0.55 A
Degree of Protection
IP20
Pollution Degree
3
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible 1/2x 0.75 ... 1 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 4 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm² Flexible 1/2x 0.75 ... 4 mm² Rigid 1/2x 0.75 ... 4 mm²
Tightening Torque
Auxiliary Circuit 1 ... 1.2 N·m Main Circuit 2.5 ... 2.7 N·m
Wire Stripping Length
Auxiliary Circuit 9 mm Main Circuit 12 mm
Recommended Screw Driver
Main Circuit Pozidriv 2
Power Loss
at Rated Operating Conditions per Pole 1.1 ... 2.0 W
Suitable For
AF09ZB AF09B AF12ZB AF12B AF16ZB AF16B AF26ZB AF26B AF30ZB AF30B AF38ZB AF38B
Standards
IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Contact Rating UL/CSA
(NC:) B600 (NC:) Q600 (NO:) Q600 (NO:) D300
Connecting Capacity Main Circuit UL/CSA
Flexible 1/2x 18-10 AWG Stranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Flexible 1/2x 18-12 AWG Stranded 1/2x 18-12 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 9 ... 11 in·lb Main Circuit 13 ... 22 in·lb
Ambient Air Temperature
Operation -25 ... +60 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C
Ambient Air Temperature Compensation
Yes
Maximum Operating Altitude Permissible
2000 m
Shock and Vibration Withstand acc. to IEC 61373
Category 1, Class B
Resistance to Shock acc. to IEC 60068-2-27
11 ms Pulse 25g
Resistance to Vibrations
5g 3 ... 150 Hz
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
2CMT2023-006525
Object Classification Code
F
ETIM 5
EC000106 - Thermal overload relay
ETIM 6
EC000106 - Thermal overload relay
ETIM 7
EC000106 - Thermal overload relay
ETIM 8
EC000106 - Thermal overload relay
eClass
V11.0 : 27371501
UNSPSC
39121520
IDEA Granular Category Code (IGCC)
5364 >> Overload relay
Manufacturer ID
1SAZ741201R1043