Key Features
- 1Provide reliable overload protection with trip class 10. 2、Detect phase loss sensitivity for comprehensive motor safety. 3、Adjust current settings for customizable overload protection. 4、Select automatic or manual reset for operational flexibility. 5、Ensure versatility in three- and single-phase applications.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product Net Width | 45 mm | Product Net Height | 88.3 mm |
| Product Net Depth / Length | 70.5 mm | Product Net Weight | 0.13 kg |
| Setting Range | 7.6 ... 10 A | Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC Main Circuit 690 V AC |
| Rated Operational Current (Ie) | 10 A | Rated Frequency (f) | Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV Main Circuit 6 kV | Rated Insulation Voltage (Ui) | 690 V |
| Number of Poles | 3P | Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 | Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (Ith) | Auxiliary Circuit NC 6 A Auxiliary Circuit NO 4 A Main Circuit 0 A | Rated Operational Current AC-15 (Ie) | (120 V) NC 3 A (120 V) NO 0.75 A (240 V) NC 3 A (240 V) NO 0.75 A (400 V) NC 0.75 A (400 V) NO 0.75 A (500 V) NC 0.75 A (500 V) NO 0.75 A |
| Rated Operational Current DC-13 (Ie) | (125 V) NC 0.55 A (125 V) NO 0.55 A (24 V) NC 1.25 A (24 V) NO 1.25 A (250 V) NC 0.27 A (250 V) NO 0.27 A (500 V) NC 0.15 A (500 V) NO 0.15 A (60 V) NC 0.55 A (60 V) NO 0.55 A | Degree of Protection | IP20 |
| Pollution Degree | 3 | Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible 1/2x 0.75 ... 1 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 0.75 ... 4 mm² |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 4 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm² Flexible 1/2x 0.75 ... 4 mm² Rigid 1/2x 0.75 ... 4 mm² | Tightening Torque | Auxiliary Circuit 1 ... 1.2 N·m Main Circuit 2.5 ... 2.7 N·m |
| Wire Stripping Length | Auxiliary Circuit 9 mm Main Circuit 12 mm | Recommended Screw Driver | Main Circuit Pozidriv 2 |
| Power Loss | at Rated Operating Conditions per Pole 1.1 ... 2.0 W | Suitable For | AF09ZB AF09B AF12ZB AF12B AF16ZB AF16B AF26ZB AF26B AF30ZB AF30B AF38ZB AF38B |
| Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L | Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NC:) B600 (NC:) Q600 (NO:) Q600 (NO:) D300 | Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 18-10 AWG Stranded 1/2x 18-10 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG Stranded 1/2x 18-12 AWG | Tightening Torque UL/CSA | Auxiliary Circuit 9 ... 11 in·lb Main Circuit 13 ... 22 in·lb |
| Ambient Air Temperature | Operation -25 ... +60 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C | Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m | Shock and Vibration Withstand acc. to IEC 61373 | Category 1, Class B |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g | Resistance to Vibrations | 5g 3 ... 150 Hz |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 | Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| Object Classification Code | F | ETIM 5 | EC000106 - Thermal overload relay |
| ETIM 6 | EC000106 - Thermal overload relay | ETIM 7 | EC000106 - Thermal overload relay |
| ETIM 8 | EC000106 - Thermal overload relay | eClass | V11.0 : 27371501 |
| UNSPSC | 39121520 | IDEA Granular Category Code (IGCC) | 5364 >> Overload relay |
| Manufacturer ID | 1SAZ741201R1043 |