VB7A-40-00-80
Product ID:69109
Updated: 2026/4/3

Key Features
- 1Control three-phase motors up to 5.5 kW reliably. 2、Utilize a compact 4-pole design with screw terminals. 3、Enhance safety with mechanical interlock and blocking. 4、Install easily with integrated DIN rail mounting. 5、Operate silently with clear switch position indication.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product Net Width | 96.2 mm | Product Net Height | 57.5 mm |
| Product Net Depth / Length | 46.7 mm | Product Net Weight | 0.355 kg |
| Number of Poles | 4 | Mini Contactor Type | Mini Contactor |
| Rated Operational Voltage | Main Circuit 690 V AC Main Circuit 220 V DC | Rated Frequency (f) | Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit 400 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV | Rated Insulation Voltage (Ui) | 690 V acc. to UL/CSA 600 V |
| Number of Main Contacts NC | 0 | Number of Main Contacts NO | 4 |
| Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 20 A (220 / 240 V) 55 °C 16 A (380 / 440 V) 40 °C 20 A (380 / 440 V) 55 °C 16 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A | Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 3 kW (400 V) Three Phase 5.5 kW (500 V) Three Phase 5.5 kW (690 V) Three Phase, NO 3 kW |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A | Number of Auxiliary Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 | Conventional Free-air Thermal Current (Ith) | Main Circuit 20 A |
| Rated Control Circuit Voltage (Uc) | 220 ... 240 V AC | Coil Operating Limits | (acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ⤠55 °C) |
| Degree of Protection | Control Circuit Terminals IP20 Main Circuit Terminals IP20 | Pollution Degree | 3 |
| Mechanical Durability | 10000000 cycle | Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-3) 600 cycles per hour |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² | Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
| Wire Stripping Length | Control Circuit 9 mm Main Circuit 9 mm | Tightening Torque | Control Circuit 0.8 ... 1.1 N·m Main Circuit 0.8 ... 1.1 N·m |
| Recommended Screw Driver | M3 Pozidriv 1 | Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.4 W | Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC | Full Load Amps Motor Use | (115 V AC) Single Phase 13.8 A (200 V AC) Three Phase 7.8 A (220 ... 240 V AC) Three Phase 9.6 A (230 V AC) Single Phase 10 A (440 ... 480 V AC) Three Phase 7.6 A (550 ... 600 V AC) Three Phase 6.1 A |
| Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.75 Hp (200 V AC) Three Phase 2 Hp (220 ... 240 V AC) Three Phase 3 Hp (230 V AC) Single Phase 1.5 Hp (440 ... 480 V AC) Three Phase 5 Hp (550 ... 600 V AC) Three Phase 5 Hp | General Use Rating UL/CSA | (600 V AC) 16 A |
| Connecting Capacity Main Circuit UL/CSA | Stranded 1/2x 22-10 AWG | Tightening Torque UL/CSA | Control Circuit 7 in·lb Main Circuit 7 in·lb |
| Ambient Air Temperature | Operation -25 ... +55 °C Storage -40 ... +80 °C | Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g | Resistance to Vibrations | 5g 5 ... 150 Hz |
| Object Classification Code | Q | ETIM 4 | EC000010 - Starter combination |
| ETIM 5 | EC000010 - Starter combination | ETIM 6 | EC000010 - Combination of contactors |
| ETIM 7 | EC000010 - Combination of contactors | ETIM 8 | EC000010 - Combination of contactors |
| eClass | V11.0 : 27371009 | UNSPSC | 39121529 |
| Manufacturer ID | GJL1311911R8000 |
Specifications may be subject to change without notice