VBC7A-30-10-P-2.4
Product ID:69993
Updated: 2026/4/3

Key Features
- 1Maximize space with a compact design for tight panels. 2、Ensure safety with reliable mechanical interlock and blocking functions. 3、Control motors across residential, commercial, and industrial settings. 4、Simplify installation using screw terminals and soldering pins. 5、Achieve high reliability with 100,000 operational cycles.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product Net Width | 96.2 mm | Product Net Height | 57.5 mm |
| Product Net Depth / Length | 47.7 mm | Product Net Weight | 0.345 kg |
| Number of Poles | 3 | Rated Operational Voltage | Auxiliary Circuit 690 V AC Auxiliary Circuit 250 V DC Main Circuit 690 V AC Main Circuit 220 V DC |
| Rated Frequency (f) | Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC | Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 690 V acc. to UL/CSA 600 V | Number of Main Contacts NC | 0 |
| Number of Main Contacts NO | 3 | Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 12 A (220 / 240 V) 55 °C 12 A (380 / 440 V) 40 °C 12 A (380 / 440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A |
| Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 3 kW (400 V) Three Phase 5.5 kW (500 V) Three Phase 5.5 kW (690 V) Three Phase, NO 3 kW | Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A |
| Number of Auxiliary Contacts NC | 0 | Number of Auxiliary Contacts NO | 1 |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 12 A | Rated Control Circuit Voltage (Uc) | 17 ... 32 V DC |
| Coil Operating Limits | (acc. to IEC 60947-4-1) for DC supply Uc Min. ... Uc Max. (at θ ⤠55 °C) | Degree of Protection | Main Circuit Terminals IP20 |
| Pollution Degree | 3 | Mechanical Durability | 10000000 cycle |
| Minimum Switching Capacity | Auxiliary Circuit 17 V Auxiliary Circuit 5 mA | Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour (AC-15) 600 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-13) 600 cycles per hour (DC-3) 600 cycles per hour |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | Power Loss | at Rated Operating Conditions AC-1 per Pole 1.4 W |
| Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 | Remarks | No CA6 or CAF6 mountable |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC | Full Load Amps Motor Use | (115 V AC) Single Phase 13.8 A (200 V AC) Three Phase 7.8 A (220 ... 240 V AC) Three Phase 9.6 A (230 V AC) Single Phase 10 A (440 ... 480 V AC) Three Phase 7.6 A (550 ... 600 V AC) Three Phase 6.1 A |
| Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.75 Hp (200 V AC) Three Phase 2 Hp (220 ... 240 V AC) Three Phase 3 Hp (230 V AC) Single Phase 1.5 Hp (440 ... 480 V AC) Three Phase 5 Hp (550 ... 600 V AC) Three Phase 5 Hp | General Use Rating UL/CSA | (600 V AC) 12 A |
| Contact Rating UL/CSA | A600 | Ambient Air Temperature | Operation -20 ... +55 °C Storage -40 ... +80 °C |
| Maximum Operating Altitude Permissible | 2000 m | Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Resistance to Vibrations | 5g 5 ... 150 Hz | Object Classification Code | Q |
| ETIM 4 | EC000066 - Magnet contactor, AC-switching | ETIM 5 | EC000010 - Starter combination |
| ETIM 6 | EC000010 - Combination of contactors | ETIM 7 | EC000010 - Combination of contactors |
| ETIM 8 | EC000010 - Combination of contactors | eClass | V11.0 : 27371009 |
| UNSPSC | 39121529 | Manufacturer ID | GJL1313919R5101 |