XT2N 125 Ekip LSIG In=60A 4p F F UL/CSA
Product ID:85569
Updated: 2026/4/10

Key Features
- 1Equip with LSIG technology for overload, short-circuit, and earth fault protection. 2、Interrupt up to 65kA at 240V AC for extreme condition reliability. 3、Connect via ring-lug or bar for maximum installation flexibility. 4、Upgrade trip units via ABB Ability Marketplace for new functionalities. 5、Meet UL 489 and CSA C22.2 standards for global compliance.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Environmental Information | 9AKK108467A6707 | Product Net Width | 120 mm |
| Product Net Height | 130 mm | Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 1.6 kg | Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT | Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker | Suitable for Product Class | SACE Tmax XT |
| Version | F | CAD Dimensional Drawing | 1SDH002230A1002 |
| Connecting Capacity Main Circuit | Busbar 32.5..100 mm² | Current Type | AC |
| Electrical Durability | 120 cycles per hour 8000 cycle | Mechanical Durability | 240 cycles per hour 25000 cycle |
| Number of Poles | 4P | Opening Time | CB with SOR 15 ms CB with UVR 15 ms |
| Order Multiple | 1 piece | Power Loss | at Rated Operating Conditions per Pole 1.50 W |
| Rated Current (In) | 60 A | Rated Frequency (f) | 50/60 Hz |
| Rated Insulation Voltage (Ui) | 1000 V AC | Rated Operational Voltage | 690 V AC |
| Rated Uninterrupted Current (Iu) | 160 A | Rated Voltage (Ur) | 690 V AC |
| Recommended Screw Driver | Main Circuit M6 | Release | Ekip LSIG |
| Release Type | EL | Short-Circuit Performance Level | N |
| Standards | UL489 | Sub-type | XT2 |
| Terminal Connection Type | Front | Terminal Type | Bolt |
| Tightening Torque | 6 N·m | Interrupting Rating acc. to UL489 | (240 V AC) 65 A (480 V AC) 25 A (600 V AC) 18 A |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection | ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4934 >> 4 Pole Non-Interchangeable Trip Electronic Circuit Breakers | Object Classification Code | Q |
| UNSPSC | 39121616 | WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 | Manufacturer ID | 1SDA075007R1 |
Specifications may be subject to change without notice