Key Features
- 1Ensure precise control with a 3/2-way normally closed design. 2、Enhance reliability using a piloted piston spool mechanism. 3、Withstand vibration and temperature fluctuations in harsh environments. 4、Achieve 350k cycles as per ISO 19973 standard testing. 5、Simplify maintenance with a detenting manual override feature.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Width dimension | 55mm | Structural design | Piston gate valve |
| Actuation type | Electrical | Sealing principle | Soft |
| Exhaust air function | Without flow control option | Manual override | Detenting |
| Reset method | Mechanical spring | Type of control | Pilot-controlled |
| Symbol | 00991008 | Valve function | 3/2, closed, monostable |
| Operating pressure | 2.5bar 16bar | Lap | Overlap |
| C value | 15.7l/sbar | b-value | 0.33 |
| Standard nominal flow rate | 3200l/min | Duty cycle | 100% |
| Coil characteristics | 24 V DC: 2.5 W | Permissible voltage fluctuations | +/- 10 % |
| Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas | Information on operating and pilot media | Operation with oil lubrication possible (required for further use) |
| Corrosion resistance class (CRC) | 2 - Moderate corrosion stress | Note on materials | RoHS-compliant |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L | Temperature of medium | -10°C 60°C |
| Ambient temperature | -10°C 60°C | Type of mounting | Line installation With accessories |
| Mounting position | Any | Flow direction | Non-reversible |
| Product weight | 500g | Pneumatic connection 1 | 3/8 NPT |
| Pneumatic connection 2 | 3/8 NPT | Pneumatic connection 3 | G1/4 |
| Air quality class at the output | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas | Pilot air supply port | Internal |
| Electrical connection | Form C Plug as per DIN EN 175301-803 | Signal status display | With accessories |
| Seals material | NBR | Housing material | Die-cast aluminum |
| Manufacturer ID | 173906 |
Specifications may be subject to change without notice