Key Features
- 1Achieve precise control with 0.02 bar pressure hysteresis. 2、Maximize flow rates with minimal pressure drop for demanding systems. 3、Protect set values from accidental adjustment to ensure reliability. 4、Select from multiple pressure ranges to fit diverse application needs. 5、Monitor pressure in real-time with an optional sensor and display.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Size | 6 | Series | MS |
| Actuator lock | Rotary knob with detent Rotary knob with integrated lock can be closed with accessories | Mounting position | Any |
| Structural design | Pilot-controlled precision diaphragm regulator pilot-controlled piston control valve | Controller function | Outlet pressure constant With secondary exhausting |
| Symbol | 00991973 00995303 00995326 | Pressure gauge | G1/4 prepared G1/8 prepared with pressure sensor with pressure gauge with switch indicator |
| Operating pressure | 1bar 14bar | Pressure regulation range | 0.05bar 12bar |
| Max. pressure hysteresis | 0.02bar 0.05bar | Flow rate of secondary venting | 220l/min 900l/min |
| Standard nominal flow rate | 800l/min 9000l/min | DC operating voltage range | 21.6V 26.4V |
| Max. electrical power consumption | 4.2W | Max. current consumption | 0.16A |
| Nominal operating voltage DC | 24V | Residual ripple | 10 % |
| Analog input signal range | 0 - 10 V 4 - 20 mA | Certification | c UL us - Recognized (OL) |
| CE marking (see declaration of conformity) | As per EU EMC directive as per EU explosion protection directive (ATEX) As per EU RoHS directive | UKCA marking (see declaration of conformity) | To UK instructions for EMC acc. to UK EX instructions To UK RoHS instructions |
| Explosion protection certification outside the EU | EPL Db (GB) EPL Gb (GB) | Explosion prevention and protection | Zone 1 (ATEX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (UKEX) Zone 22 (ATEX) |
| ATEX category gas | II 2G | ATEX category for dust | II 2D |
| Type of ignition protection for gas | Ex h IIC T6 Gb X | Type of (ignition) protection for dust | Ex h IIIC T60°C Db X |
| Explosive ambient temperature | -10°C <= Ta <= +60°C | Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas |
| Information on operating and pilot media | Ester oil < 0.1mg/m3, according to ISO 8573-1:2010 [-:-:2] Operation with oil lubrication not possible | Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L | Storage temperature | -10°C 60°C |
| Temperature of medium | -10°C 60°C | Ambient temperature | -10°C 60°C |
| Product weight | 800g 1120g | Type of mounting | Optionally: Front panel mounting Line installation With accessories |
| Pilot air port 12 | G1/8 1/8 NPT | Pneumatic connection 1 | G1/4 G3/8 G1/2 G3/4 1/4 NPT 3/8 NPT 1/2 NPT 3/4 NPT |
| Pneumatic connection 2 | G? G3/8 G1/2 G3/4 1/4 NPT 3/8 NPT 1/2 NPT 3/4 NPT | Pneumatic connection 3 | G1/4 |
| Note on materials | RoHS-compliant | Seals material | NBR |
| Housing material | Aluminum | Manufacturer ID | 538028 |
Specifications may be subject to change without notice