Key Features
- 1Ensure explosion safety with ATEX II 2G/2D certification.
- 2Achieve high efficiency with 12W power at 60V DC.
- 3Withstand harsh conditions via IP65 and T130°C rating.
- 4Install flexibly in any position for 100% duty cycle.
- 5Meet global standards with RoHS, CE, TÜV, and INMETRO.
Need a quote? Enter your quantity and get pricing fast.
Qty
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Actuation type | Electrical | Mounting position | Any |
| Switching position indication | no | Duty cycle | 100% |
| Insulation class | H | Coil characteristics | 60 V DC: 12.0 W |
| Permissible voltage fluctuations | -15 % / +10 % | CE marking (see declaration of conformity) | As per EU RoHS directive |
| UKCA marking (see declaration of conformity) | as per UK EX instructions (UK-X) as per UK RoHS instructions (UK-R) | Explosion protection certification outside the EU | EPL Db (GB) EPL Db (IEC-EX) EPL Gb (GB) EPL Gb (IEC-EX) |
| Explosion prevention and protection | Zone 1 (ATEX) Zone 1 (IEC-EX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (IEC-EX) Zone 21 (UKEX) Zone 22 (ATEX) | Certificate issuing authority | German Technical Control Board (TüV) 21 UKEX 7017 X |
| ATEX category gas | II 2G | ATEX category for dust | II 2D |
| Type of ignition protection for gas | Ex eb mb IIC T* Gb | Type of (ignition) protection for dust | Ex tb IIIC T*°C Db |
| Explosive ambient temperature | T4/T120°C: -25°C <= Ta <= +40°C | LABS (PWIS) conformity | VDMA24364 zone III |
| Degree of protection | IP66 | Product weight | 580g |
| Electrical connection | Terminal box, cable entry thread M20x1.5 | Note on materials | RoHS-compliant |
| Manufacturer ID | 8109393 |
Specifications may be subject to change without notice