vacc-s18-35-k4-3u-ex4me
Product ID:16698
Updated: 2026/4/3

Key Features
- 1Meet ATEX/IECEx standards for hazardous area safety. 2、Achieve IP65 protection against dust and water jets. 3、Operate on 230V DC or AC with a built-in bridge rectifier. 4、Ensure reliability across a -20°C to +60°C temperature range. 5、Simplify installation with an M20x1.5 cable entry thread.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Actuation type | Electrical | Mounting position | Any |
| Switching position indication | no | Duty cycle | 100% |
| Insulation class | H | Coil characteristics | 230 V AC: 50/60 Hz, power 3.5 VA 230 V DC: 3.5 W |
| Permissible voltage fluctuations | -15 % / +10 % | CE marking (see declaration of conformity) | as per EU explosion protection directive (ATEX) As per EU RoHS directive |
| UKCA marking (see declaration of conformity) | as per UK EX instructions (UK-X) as per UK RoHS instructions (UK-R) | Explosion protection certification outside the EU | EPL Db (GB) EPL Db (IEC-EX) EPL Gb (GB) EPL Gb (IEC-EX) |
| Explosion prevention and protection | Zone 1 (ATEX) Zone 1 (IEC-EX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (IEC-EX) Zone 21 (UKEX) Zone 22 (ATEX) | Certificate issuing authority | BVS 16ATEXE036X IECEx BVS16.0028X German Technical Control Board (TüV) 21 UKEX 7017 X |
| ATEX category gas | II 2G | ATEX category for dust | II 2D |
| Type of ignition protection for gas | Ex eb mb IIC T* Gb | Type of (ignition) protection for dust | Ex tb IIIC T*°C Db |
| Explosive ambient temperature | T5/T95°C: -25°C <= Ta <= +60°C T6/T80°C: -25°C <= Ta <= +50°C | LABS (PWIS) conformity | VDMA24364 zone III |
| Degree of protection | IP66 | Product weight | 580g |
| Electrical connection | Terminal box, cable entry thread M20x1.5 | Note on materials | RoHS-compliant |
| Manufacturer ID | 8109386 |