vzwd-l-m22c-m-g14-20-v-3ap4-40-r1
Product ID:1850
Updated: 2026/4/3

Key Features
- 1Control compressed air flow precisely with direct poppet valve design. 2、Ensure reliable operation via electric actuation in industrial settings. 3、Simplify installation and reduce vibration with soft mounting. 4、Handle diverse media including compressed air, inert gases, and oils. 5、Resist corrosion with durable cast brass construction and FPM seals.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Structural design | Directly controlled poppet valve | Actuation type | Electrical |
| Sealing principle | Soft | Mounting position | Any |
| Type of mounting | Line installation | Fitting connection | G1/4 |
| Electrical connection | Form A Plug as per EN 175301-803 Rectangular design | Nominal width | 2mm |
| Valve function | 2/2, closed, monostable | Manual override | None |
| Flow direction | Non-reversible | Medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas Mineral oil Water Neutral liquids Other flow media on request |
| Nominal pressure of fitting PN | 100 | Pressure difference | 0psi |
| Differential pressure | 0bar | Coil characteristics | 230 V AC: 50/60 Hz, initial power 18.0 VA, holding power 15.0 VA |
| Insulation class | F | Permissible voltage fluctuations | +/- 10 % |
| Duty cycle | 100% | Reset method | Mechanical spring |
| Type of control | Direct | Symbol | 00992979 |
| Medium pressure | 0psi 580psi | Max. viscosity | 22mm2/s |
| Temperature of medium | -10°C 80°C | Ambient temperature | -10°C 35°C |
| Leak rate to EN 12266-1 | A | Flow rate Kv | 0.13m3/h |
| Standard nominal flow rate | 140l/min | On switching time | 20ms |
| Switching time off | 18ms | Note on materials | RoHS-compliant |
| LABS (PWIS) conformity | VDMA24364 zone III | Housing material | High-alloy stainless steel |
| Material number of housing | 1.4305 | Seals material | FPM |
| Product weight | 650g | CE marking (see declaration of conformity) | As per EU low voltage directive |
| UKCA marking (see declaration of conformity) | To UK instructions for electrical equipment | Degree of protection | IP65 |
| Corrosion resistance class (CRC) | 3 - High corrosion stress | Manufacturer ID | 1492014 |
Specifications may be subject to change without notice