vzwd-l-m22c-m-n14-25-v-1p4-22
Product ID:1718
Updated: 2026/4/3

Key Features
- 1Control compressed air flow precisely with a direct poppet valve design. 2、Actuate reliably using an electrical mechanism for efficient operation. 3、Reduce vibration and noise with a soft mounting design for system stability. 4、Handle diverse media like compressed air, inert gases, and neutral liquids. 5、Support high-pressure applications with a nominal pressure rating of 22 bar.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Structural design | Directly controlled poppet valve | Actuation type | Electrical |
| Sealing principle | Soft | Mounting position | Any |
| Type of mounting | Line installation | Fitting connection | NPT1/4 |
| Electrical connection | Form A Plug as per EN 175301-803 Rectangular design | Nominal width | 2.5mm |
| Valve function | 2/2, closed, monostable | Manual override | None |
| Flow direction | Non-reversible | Medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas Mineral oil Water Neutral liquids Other flow media on request |
| Nominal pressure of fitting PN | 100 | Differential pressure | 0bar |
| Coil characteristics | 24 V DC: 11.0 W | Insulation class | H |
| Permissible voltage fluctuations | +/- 10 % | Duty cycle | 100% |
| Reset method | Mechanical spring | Type of control | Direct |
| Symbol | 00992979 | Medium pressure | 0bar 22bar |
| Max. viscosity | 22mm2/s | Temperature of medium | -10°C 80°C |
| Ambient temperature | -10°C 35°C | Leak rate to EN 12266-1 | A |
| Flow rate Kv | 0.16m3/h | Standard nominal flow rate | 170l/min |
| On switching time | 20ms | Switching time off | 18ms |
| Note on materials | RoHS-compliant | LABS (PWIS) conformity | VDMA24364 zone III |
| Housing material | Cast brass | Material number of housing | CW617N |
| Seals material | FPM | Product weight | 550g |
| Degree of protection | IP65 | Corrosion resistance class (CRC) | 1 - Low corrosion stress |
| Manufacturer ID | 1491882 |
Specifications may be subject to change without notice