  • 1Supports up to 16 devices: Ideal for connecting multiple standard or PCP devices on a local bus.
  • 28 Digital Inputs: Includes 8 digital inputs for various applications, ensuring comprehensive data collection.
  • 3Dynamic Configuration: Allows for channel-specific diagnostics and dynamic configuration for flexible setup.
  • 4M12 Fast Connection Technology: Utilizes M12 connectors with SPEEDCON fast locking system for secure and efficient connections.
  • 5IP65/IP67 Protection: Offers robust protection against dust and water, ensuring reliable operation in harsh environments.
Product Details
FLM BK PB M12 DI 8 M12-EF
Phoenix Contact

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Width
70 mm
Height
178 mm
Depth
50 mm
Drill hole spacing
168 mm
Color
anthracite
Connection method
M12 connector, B-coded
Designation connection point
Copper cable
Number of positions
5
Transmission speed
9.6 kbps ... 12 Mbps
Address area assignment
1 ... 126, adjustable
Designation
Local bus gateway
Connection method
M12 connector, B-coded
Transmission speed
500 kbaud/2 Mbaud, can be selected
Max. length of local bus
20 m
Max. number of local bus devices
16
Number of local bus devices that can be connected
max. 16
Number of devices with parameter channel
max. 16
Input address area
8 bit
Output address area
1 Byte
Register length
8 bit
Input name
Digital inputs
Description of the input
IEC 61131-2 type 1
Number of inputs
8 (double-occupancy)
Connection method
M12 connector
Connection technology
2-, 3-, 4-conductor
Input voltage
24 V DC
Input voltage range "0" signal
-30 V DC ... 5 V DC
Input voltage range "1" signal
13 V DC ... 30 V DC
Nominal input voltage U
24 V DC
Filter time
3 ms
Protective circuit
Reverse polarity protection
Product type
I/O component
Product family
Fieldline
Type
modular
No. of channels
8
Voltage supply U
24 V DC
Power supply at U
max. 4 A
Current consumption from U
max. 100 mA (At 2 Mbaud) typ. 75 mA (At 2 Mbaud) max. 100 mA (At 500 kBaud) typ. 75 mA (At 500 kBaud)
Voltage supply U
24 V DC
Power supply at U
max. 4 A
Current consumption from U
typ. 15 mA (plus power supply for sensors) max. 600 mA
Connection method
M12 connector
Designation
U
Supply voltage
24 V DC
Supply voltage range
18 V DC ... 30 V DC (including ripple)
Test voltage: To I/O
500 V AC
Connection method
M12 connector
Ambient temperature (operation)
-25 °C ... 60 °C
Degree of protection
IP65/IP67
Air pressure (operation)
80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (storage/transport)
95 %
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
Wall mounting, optionally on mounting panel Wall mounting

Specifications may be subject to change without notice