IB IL SGI 2/F

Product ID:20427
Updated: 2026/7/31
Phoenix Contact IB IL SGI 2/F

Key Features

  • 1High-Speed Data Processing: The terminal supports bus-synchronous process data update, ensuring fast and accurate data transfer.
  • 2Dual Input Channels: Equipped with two fast inputs for connecting strain gauges, ideal for load cells, force transducers, and mass pressure transducers.
  • 3Flexible Connection Options: Supports both 6- and 4-wire connection methods for strain gauges, providing versatility in setup.
  • 4Integrated Power Supply: Sensor supply voltage is provided by the terminal, eliminating the need for an external power supply.
  • 5Robust Design: Designed for operation in a wide range of ambient conditions, including temperatures from -25°C to 55°C and humidity levels up to 95%.

Need price and lead time?

Request a quote for original Phoenix Contact IB IL SGI 2/F. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original Phoenix Contact
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Type
modular
Operating mode
Process data operation with 3 words, PCP with 1 word
ID code (dec.)
223
ID code (hex)
DF
Length code (hex)
03
Length code (dec)
03
Process data channel
48 bit
Input address area
48 bit
Output address area
48 bit
Register length
32 bit
Required parameter data
15 Byte
Required configuration data
5 Byte
Power consumption
typ. 0.76 W
Supply voltage
7.5 V DC (via voltage jumper)
Current draw
max. 85 mA typ. 75 mA
Supply voltage
24 V DC (via voltage jumper)
Supply voltage range
19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw
typ. 32 mA (with maximum load of 58.3 Ω when U typ. 8 mA (without strain gauge)
Test voltage: Logic/analog I/O (digital isolator)
500 V AC, 50 Hz, 1 min
Test voltage: Functional ground/analog I/O (isolating distance)
500 V AC, 50 Hz, 1 min
Test voltage: Logic/functional ground (isolating distance)
500 V AC, 50 Hz, 1 min
Description of the input
Input channels for strain gauge
Number of inputs
2
Connection technology
6 or 4-wire, twisted pair shielded cable
Bridge difference U
Measuring range specified by selecting the characteristic and the bridge voltage
Bridge voltage U
3.3 V 5 V
Measured value representation
15 bit + sign bit
Characteristics
±1 mV/V, ±2 mV/V, ±3 mV/V, ±4 mV/V +1 mV/V, +2 mV/V, +3 mV/V, +4 mV/V
Output description
Voltage output
Number of outputs
2
Impedance
> 58.3 Ω (typical; permissible total resistance of the strain gauge)
Output voltage
typ. 5 V 3.3 V
Output current
typ. 55 mA (with U typ. 85 mA (with U
Connection method
Spring-cage connection
Conductor cross section, rigid
0.08 mm² ... 1.5 mm²
Conductor cross section, flexible
0.08 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Connection method
Inline data jumper
Transmission speed
500 kbps
Transmission physics
Copper
Width
48.8 mm
Height
119.8 mm
Depth
71.5 mm
Color
green
Ambient temperature (operation)
-25 °C ... 55 °C
Degree of protection
IP20
Air pressure (operation)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)
70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)
-25 °C ... 85 °C
Permissible humidity (operation)
10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)
10 % ... 95 % (according to DIN EN 61131-2)
Protection class
III (IEC 61140, EN 61140, VDE 0140-1)
Mounting type
DIN rail mounting

Specifications may be subject to change without notice

Still deciding on IB IL SGI 2/F?

Our engineers can confirm stock, price, and lead time for this Phoenix Contact part.

Get a no-obligation quote in 1 minute.

Chat with us