PLC-RSP- 60DC/21-21AU

Product ID:20036
Updated: 2026/7/31
Phoenix Contact PLC-RSP- 60DC/21-21AU

Key Features

  • 1Handles up to 6 A continuous current and 15 A inrush current.
  • 2Constructed with Ag alloy, hard gold-plated contacts for durability.
  • 3Ensures high reliability with a typical response time of 5 ms and 8 ms typical release time.
  • 4Equipped with polarity protection diode for safe operation.
  • 5Compatible with DIN rail NS 35/7.5 and available in a compact size for easy integration.

Need price and lead time?

Request a quote for original Phoenix Contact PLC-RSP- 60DC/21-21AU. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original Phoenix Contact
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
EMC note
EMC: class A product, see manufacturer's declaration in the download area
Product type
Relay Module
Product family
PLC-INTERFACE
Application
Universal
Operating mode
100% operating factor
Mechanical service life
3x 10
Date of last data management
10.10.2023
Insulation
Basic insulation
Overvoltage category
III
Pollution degree
2
Maximum power dissipation for nominal condition
0.6 W
Rated surge voltage
6 kV
Nominal input voltage U
60 V DC
Input voltage range
51 V DC ... 84 V DC
Typical input current at U
10 mA
Typical response time
8 ms
Typical release time
10 ms
Protective circuit
Reverse polarity protection; Polarity protection diode Freewheeling diode; Freewheeling diode
Operating voltage display
Yellow LED
Contact switching type
2 changeover contacts
Type of switch contact
Single contact
Contact material
AgNi, hard gold-plated
Maximum switching voltage
30 V AC 36 V DC
Minimum switching voltage
100 mV (at 10 mA)
Limiting continuous current
50 mA
Maximum inrush current
50 mA
Min. switching current
1 mA (at 24 V)
Interrupting rating (ohmic load) max.
1.2 W (at 24 V DC)
Note
Maximum switching voltage
250 V AC/DC
Minimum switching voltage
5 V AC/DC
Limiting continuous current
6 A
Maximum inrush current
15 A (300 ms)
Min. switching current
10 mA
Interrupting rating (ohmic load) max.
140 W (at 24 V DC) 85 W (at 48 V DC) 60 W (at 60 V DC) 44 W (at 110 V DC) 60 W (at 220 V DC) 1500 VA (for 250 V AC)
Switching capacity
2 A (at 24 V, DC13) 0.2 A (at 110 V, DC13) 0.2 A (at 250 V, DC13) 2 A (at 24 V, AC15) 2 A (at 120 V, AC15) 2 A (at 250 V, AC15)
Connection method
Spring-cage connection
Stripping length
8 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
26 ... 14
Connection method
Spring-cage connection
Stripping length
8 mm
Conductor cross section rigid
0.14 mm² ... 2.5 mm²
Conductor cross section flexible
0.14 mm² ... 2.5 mm²
Conductor cross section AWG
26 ... 14
Width
14 mm
Height
80 mm
Depth
94 mm
Color
green (RAL 6021)
Flammability rating according to UL 94
V0 (Housing)
Degree of protection (Relay)
RT III (Relay)
Degree of protection (Relay base)
IP20 (Relay base)
Ambient temperature (operation)
-40 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Standards/regulations
IEC 60664 IEC 60947-5-1
Mounting type
DIN rail mounting
Assembly note
in rows with zero spacing
Mounting position
any

Specifications may be subject to change without notice