  • 11. Compact Design: The Allen Bradley 150-C16NBD is designed to be compact, making it easy to integrate into various industrial settings without taking up too much space.;
  • 22. Superior Speed Control: This smart motor controller features true three-phase control, providing superior speed control and a smoother, safer motor start-up and stop.;
  • 33. Reliable Operation: Equipped with a built-in overload relay, the 150-C16NBD ensures reliable operation and protects your motor from overloads, extending its lifespan.;
  • 44. Wide Voltage Compatibility: Compatible with 100-240V AC, 50/60 Hz, this controller can be used in a variety of environments, making it versatile for different industrial applications.;
  • 55. Efficient Energy Use: By providing a smooth start-up and stop, the Allen Bradley 150-C16NBD helps reduce energy consumption, making it an efficient choice for industrial motor control systems.

Need price and lead time?

Request a quote for original Rockwell Automation 150-C16NBD. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original Rockwell Automation
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Dimension Unit
CM
Weight Unit
KG
Stock Status
STOCKED
Dimension Length
18.009
Dimension Width
18.491
Lead Time
5
Dimension Height
9.195
Quick Turnaround
false
Preferred Availability
true
Repairable
NOT_REPAIRABLE
Enclosure
Open type
Number of poles
Equipment is designed for 3-phase only for power circuit
Mounting hole size
4.6 mm
Pollution degree
2
Altitude
2000 m
EMC immunity levels
Surge transient: per EN/IEC 60947-4-2 per IEC
EMC emission levels
Radiated emission: Class A per IEC
Operating temperature
Open: -5 to 50 °C (23 to 122 °F)
Humidity
5...95% noncondensing
Rated surrounding temperature range without derating
-5 °C
Storage and transportation temperature
-25 °C
Steady state heat dissipation
14 W
Selectable soft stop
Off, 100%, 200%, or 300% of the start time setting when wired
Selectable initial torque
15%, 25%, 35%, and 65% of locked rotor torque
Selectable kick start - 450% FLA
0, 0.5, 1.0, or 1.5 s
Function
Single direction
Internal bypass
Yes
Tightening torque
2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm2 (4 AWG) wire in top terminal for line power terminal
Break
TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts
Make
TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts
Vibration
Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement
Cable size
2.5...25 mm2 (14...4 AWG) for line power terminals
Height
139.7 mm (5.5 in)
Depth
110 mm (4.33 in)
Width
44.8 mm (1.76 in)
Shock
Opsal: 15 G
Weight
0.909
Degree of protection (IP)
IP2X
Input ON-state current (IN1, IN2)
9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit
Rated control power during start without fan
205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC
Input ON-state voltage, during start (IN1, IN2)
85V AC @ 19.2V DC/19.2V AC minimum for control circuit
Selectable current limit
150%, 250%, 350%, and 450% of full load current
Input OFF-state voltage (IN1, IN2), max
40V AC @ 17V DC/12V AC for control circuit
Selectable start times
2, 5, 10, 15, 20, 25, or 30 s
Selectable overload trip class
Trip Class 10, 15, or 20
Short circuit protection device performance (SCPD) type
Type 1
Integrated motor overload protection
Yes
Standard available fault current, max
5 kA @ maximum standard fuse 70 A for delta device opsal current rating
Standard controller feature
Soft stop
Rated operational current, max
TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts
Utilization category
TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts
Type of contacts
TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts
Type of control circuit
TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts
Conventional thermal current (Ith)
TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts
Type of current
TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts
High capacity available fault current, max
69kA @ 600V, maximum current 60 A time delay Class J or Class L fuse for inside delta connected motors
Number of contacts
TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts
Short-circuit protection device list
Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L
Input OFF-state current
<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit
Rated control power during start with fan
215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC
Rated operational voltage
250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts
Insulation voltage
Rated 600V AC per UL/CSA/NEMA for power circuit
Delta connected motor current
9.1...27.6A @ 380/400/415/460V AC, 3-phase
Line connected motor current
5.3...16A @ 380/400/415/460V AC, 3-phase
Dielectric withstand
2500V AC per IEC for power circuit
Rated impulse voltage
6 kV for power circuit
Overvoltage category
III per IEC for side mount auxiliary contacts
Delta connected motor power, max
5...15Hp @ 460V AC, 60 Hz, 3-phase
Line connected motor power, max
7.5 kW @ 380/400/415V AC @ 50Hz, 3-phase
Operating frequency
50/60 Hz per UL/CSA/NEMA for power circuit
Repetitive peak voltage
1400V per UL/CSA/NEMA for power circuit
DV/DT protection
1000V/μs for power circuit
Controller type
SMC-3
Overload current
5.3 A
Rated control supply voltage at AC 60 Hz
100
Rated control supply voltage at AC 50 Hz
100
Rated operating voltage Ue
200
Voltage type for actuating
AC/DC
With display
No
Product Family
SMC-3

Specifications may be subject to change without notice

Still deciding on 150-C16NBD?