140ACO02000C

Product ID:23743
Updated: 2026/7/14
schneider 140ACO02000C

Key Features

  • 1Deliver high-precision analog output with +/- 0.20% full-scale accuracy.
  • 2Ensure safety with 750 V DC isolation between all channels.
  • 3Achieve fast 3 ms update times for responsive control.
  • 4Operate reliably with a wide 12-30 V DC loop voltage range.
  • 5Maximize energy efficiency with low <=5.3 W power dissipation.

Need price and lead time?

Request a quote for original schneider 140ACO02000C. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original schneider
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Modicon Quantum automation platform
Product or Component Type
Analogue output module
Analogue output number
4
Addressing requirement
4 output words
Loop voltage
12…30 V DC
Maximum voltage drop
<30 V 20 mA
Analogue output range
4...20 mA 0...4096 counts, 12 bits bipolar current
Absolute accuracy error
+/- 0.20 % of full scale 77 °F (25 °C)
Linearity
+/- 1 LSB
Accuracy drift according to temperature
+/- 0.004 % of full scale/°C<br />+/- 0.007 % of full scale/°C maximum
Isolation between channels
500 V 47...63 Hz AC<br />750 V for 1 minute DC
Update time
3 ms
Setting time
900 µs to +/- 0.1 % of the final value
Fault type
Open circuit 4...20 mA
Bus current requirement
480 mA
Maximum power dissipation in W
5.3 W
External power requirement
12...30 V
marking
CE
Local signalling
for bus communication is present (Active) 1 LED (green)<br /> for external fault 1 LED (red)<br /> for channel is turned on 4 LEDs (green)<br /> for channel fault 4 LEDs (red)
Module format
Standard
Net Weight
0.7 lb(US) (0.3 kg)
Protective treatment
Conformal coating Humiseal 1A33
Product Certifications
cUL<br />FM Class 1 Division 2
Standards
CSA C22.2 No 142<br />UL 508
Resistance to electromagnetic fields
9.1 V/m (10 V/m) 80…2000 MHz IEC 801-3
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative Humidity
95 % without condensation
Operating altitude
<= 16404.2 ft (5000 m)