140AII33000C

Product ID:23747
Updated: 2026/7/14
schneider 140AII33000C

Key Features

  • 1Ensure safety in hazardous areas with intrinsically safe design.
  • 2Achieve precise measurements across 8 dedicated temperature channels.
  • 3Integrate seamlessly with the Modicon Quantum automation series.
  • 4Operate reliably in a wide temperature range from -20°C to +60°C.
  • 5Power your system robustly with a stable 15.5VDC supply.

Need price and lead time?

Request a quote for original schneider 140AII33000C. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original schneider
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Modicon Quantum automation platform
Product or Component Type
Intrinsically safe temperature input module
Software designation
Concept V2.2 and above<br />Unity Pro
Type of filter
Plus notch input filter 50/60 Hz thermocouple<br />Single low pass input filter 20 Hz thermocouple
Product destination
In conjunction with products for zone 20, 21 or 22
Analogue input number
8
Analogue input type
Low level voltage -100...100 mV<br />Low level voltage -25...25 mV<br />Thermocouple - 210...760 °C thermocouple J<br />Thermocouple - 270...1000 °C thermocouple E<br />Thermocouple - 270...1370 °C thermocouple K<br />Thermocouple - 270...400 °C thermocouple T<br />Thermocouple - 50...1665 °C thermocouple R<br />Thermocouple - 50...1665 °C thermocouple S<br />Temperature probe - 200...850 °C Pt 100, Pt 200, Pt 500, Pt 1000<br />Temperature probe - 60...180 °C Ni 100, Ni 200, Ni 500, Ni 1000<br />Thermocouple - 130...1820 ° C thermocouple B
Measurement current
0.5 mA Pt 500, Pt 1000, Ni 500, Ni 1000<br />2.5 mA Pt 100, Pt 200, Ni 100, Ni 200
Source resistance
< 200 Ohm thermocouple
Input impedance
> 10 MOhm RTD<br /> thermocouple
Common mode rejection
> 100 dB 50/60 Hz RTD<br />> 120 dB 50/60 Hz thermocouple
Cold junction compensation
Internal 32.0000000000…140.0000000000 °F (0…60 °C) thermocouple
Linearity
0.003 % of full scale RTD
Resolution
0.76 µV (16 bits) -25...25 mV millivolt<br />3.05 µV (16 bits) -100...100 mV millivolt<br />1 °C, 0.1 °C, 1 °F, 0.1 °F thermocouple<br />12 bits + sign (0.1 °C) RTD
Measurement accuracy
+/- 2 °C + 0.1 % of reading thermocouple E<br />+/- 2 °C + 0.1 % of reading thermocouple J<br />+/- 2 °C + 0.1 % of reading thermocouple K<br />+/- 2 °C + 0.1 % of reading thermocouple T<br />+/- 4 °C + 0.1 % of reading thermocouple B<br />+/- 4 °C + 0.1 % of reading thermocouple R<br />+/- 4 °C + 0.1 % of reading thermocouple S<br />+/- 0.5 °C RTD 77.0000000000 °F (25 °C)<br />+/- 0.9 °C RTD 32.0000000000…140.0000000000 °F (0…60 °C)<br />20 µV + 0.1 % of reading millivolt 77.0000000000 °F (25 °C)
Absolute accuracy error
+/- 0.05 % of full scale RTD 77.0000000000 °F (25 °C)<br />+/- 0.1 % of full scale maximum RTD 77.0000000000 °F (25 °C)
Accuracy drift according to temperature
0.15 mV/°C + 0.0015 % of reading/°C max thermocouple
Update time
1 s TC/millivolt thermocouple<br />1.35 s 3 wires RTD<br />750 ms 2 or 4 wires RTD
Isolation between channels and bus
1780 V 47...63 Hz AC for 1 minute<br />2500 V DC for 1 minute
Fault type
Out of range<br />Broken wire
Power dissipation in W
2 W
Hot swapping fallback
Not allowed per intrinsic safety standards
Protection Type
Internal fuse
marking
CE<br />II1 G/D-EEx ia IIC
Bus current requirement
400 mA
Module format
Standard
Net Weight
0.7 lb(US) (0.3 kg)
Protective treatment
Conformal coating Humiseal 1A33
Standards
EN 50281-1-1<br />EN 50284<br />Directive ATEX 94/9/EC<br />EN 50020<br />EN 50014<br />CSA C22.2 No 142<br />EN 50039
Dust zone
Outside zone
Product Certifications
SIRA 02ATEX2345X<br />FM Class 1 Division 2<br />hazardous location class 1, division 1 groups A, B, C<br />C-Tick.1
Resistance to electrostatic discharge
4 kV contact IEC 801-2<br />8 kV on air IEC 801-2
Resistance to electromagnetic fields
9.1 V/m (10 V/m) 80…2000 Hz IEC 801-3
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative Humidity
95 % without condensation
Operating altitude
<= 16404.2 ft (5000 m)

Specifications may be subject to change without notice