140ATI03000C

Product ID:23757
Updated: 2026/4/3
schneider 140ATI03000C

Key Features

  • 1Measure temperatures using various thermocouples with high 16-bit accuracy. 2、Provide robust 1780V AC isolation between channels and bus for safety. 3、Equip with 20Hz low-pass and 50/60Hz notch filters to minimize noise. 4、Ensure reliable readings with precise analog input resolution. 5、Consume only 1.5W power for energy-efficient industrial operation.
Product Details
140ATI03000C
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Modicon Quantum automation platform
Product or Component Type
Analogue input module
Type of filter
Notch filter - 3 dB at 50/60 Hz<br />Single pole low pass - 3 dB at 20 Hz
Analogue input number
8
Addressing requirement
10 input words
Analogue input type
Thermocouple - 210...760 °C thermocouple J<br />Thermocouple - 270...1000 °C thermocouple E<br />Thermocouple - 270...1370 °C thermocouple K<br />Thermocouple - 270...400 °C thermocouple T<br />Thermocouple - 50...1665 °C thermocouple R<br />Thermocouple - 50...1665 °C thermocouple S
Analogue input resolution
16 bits
Absolute accuracy error
+/- 2 °C plus + 0.1 % of reading thermocouple E<br />+/- 2 °C plus + 0.1 % of reading thermocouple J<br />+/- 2 °C plus + 0.1 % of reading thermocouple K<br />+/- 2 °C plus + 0.1 % of reading thermocouple T<br />+/- 4 °C plus + 0.1 % of reading thermocouple R<br />+/- 4 °C plus + 0.1 % of reading thermocouple S
Linearity error
1 °C, 0.1 °C, 1 F, 0.1 F - 210...760 °C<br />1 °C, 0.1 °C, 1 F, 0.1 F - 270...1000 °C<br />1 °C, 0.1 °C, 1 F, 0.1 F - 270...1370 °C<br />1 °C, 0.1 °C, 1 F, 0.1 F - 270...400 °C<br />1 °C, 0.1 °C, 1 F, 0.1 F - 50...1665 °C
Accuracy drift according to temperature
0.15 µV/°C + 0.0015 % of reading/°C max low level voltage
Common mode rejection
> - 120 dB 50/60 Hz
Isolation between channels and bus
1780 V AC 60 s<br />2500 V DC 60 s
Isolation between channels
300 V DC<br />220 V AC
Update time
1000 ms
Fault type
Broken wire<br />Overtacking scale
marking
CE
Cold junction compensation
Internal 32…140 °F (0…60 °C)
Local signalling
for bus communication is present (Active) 1 LED (green)<br /> for external fault 1 LED (red)<br /> for channel is turned on 8 LEDs (green)<br /> for channel fault 8 LEDs (red)
Bus current requirement
280 mA
Power dissipation in W
1.5 W
Module format
Standard
Net Weight
0.7 lb(US) (0.3 kg)
Protective treatment
Conformal coating Humiseal 1A33
Standards
UL 508<br />CSA C22.2 No 142
Product Certifications
cUL<br />FM Class 1 Division 2
Resistance to electrostatic discharge
4 kV contact IEC 801-2<br />8 kV on air IEC 801-2
Resistance to electromagnetic fields
9.1 V/m (10 V/m) 80…1000 MHz IEC 801-3
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative Humidity
95 % without condensation
Operating altitude
<= 16404.2 ft (5000 m)

Specifications may be subject to change without notice