140DDI15310

Product ID:25890
Updated: 2026/7/14
schneider 140DDI15310

Key Features

  • 1Detect signals accurately with a 4.5-5.5V DC input range.
  • 2Prevent interference using 1780 VRMS robust isolation.
  • 3Process real-time changes with ≤500 µs response time.
  • 4Monitor status via 32 green LEDs and fault indicators.
  • 5Reduce energy consumption with a 5W power dissipation design.

Need price and lead time?

Request a quote for original schneider 140DDI15310. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original schneider
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Modicon Quantum automation platform
Product or Component Type
Low voltage dc discrete input modules
Discrete input number
32
Group of channels
4
Logic input
Negative (source)
Discrete input voltage
5 V TTL DC
input voltage limits
4.5...5.5 V
Voltage state 1 guaranteed
0.8 V DC
Voltage state 0 guaranteed
>= 4 V DC at 5.5 V supply voltage
Current state 1 guaranteed
4 mA
Addressing requirement
2 input words
input impedance
7500 Ohm
Maximum leakage current
200 mA at Us = 5.5 V and Uin = 4 V
Absolute maximum input
15 V during 1.3 ms decaying pulse<br />5.5 V continuous
Response Time
<= 250 µs from state 0 to state 1<br /><= 500 µs from state 1 to state 0
Protection Type
Input protection
Power dissipation
5 W
Isolation between group and bus
1780 Vrms for 1 minute
Isolation between group
500 Vrms for 1 minute
Local signalling
for bus communication is present (Active) 1 LED (green)<br /> for external fault detected (F) 1 LED (red)<br /> for input status 32 LEDs (green)
marking
CE
Bus current requirement
170 mA
Module format
Standard
Net Weight
0.99 lb(US) (0.45 kg)
Standards
CSA C22.2 No 142<br />UL 508
Product Certifications
GOST<br />FM Class 1 Division 2<br />cUL
Resistance to electrostatic discharge
4 kV contact IEC 801-2<br />8 kV on air IEC 801-2
Resistance to electromagnetic fields
9.1 V/m (10 V/m) 80…2000 MHz IEC 801-3
Ambient Air Temperature for Operation
32…140 °F (0…60 °C)
Ambient Air Temperature for Storage
-40…185 °F (-40…85 °C)
Relative Humidity
95 % without condensation
Operating altitude
<= 16404.2 ft (5000 m)

Specifications may be subject to change without notice