140NOA62200
Product ID:29393
Updated: 2026/4/3

Key Features
- 1Enable high-performance communication at 500 kbit/s. 2、Ensure compatibility with Quantum CPUs like 140CPU11303. 3、Utilize advanced LED diagnostics for fault monitoring. 4、Integrate seamlessly with Concept and ProWORX 32 software. 5、Connect reliably using a durable SUB-D 9 connector.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Modicon Quantum automation platform | Product or Component Type | Interbus master module |
| Software Designation | Concept<br />ProWORX 32 | Software Version | V 2.5 SR2 |
| Module type | Interbus generation 4 | Format | Standard |
| Product Compatibility | 140CPU11303<br />140CPU43412A<br />140CPU53414B | Product Specific Application | For standard applications |
| Module profile | PCP V2.0 | Method of access | Master |
| Communication port protocol | Interbus RS485 isolated 500 kbit/s DIN 66020<br />Serial link | Type of Cable | Twisted pair |
| Maximum cable distance between devices | 65.6 ft (20 m) | Memory capacity | 128 kB + 256 kB firmware EPROM<br />2 kB dual-port RAM RAM<br />256 kB + 32 kB for data RAM<br />64 kB Interbus command sequence EEPROM<br />64 kB multi-port RAM RAM |
| Bus current requirement | 800 mA | Product compatibility | 6 x 140CPU11303 Interbus local rack<br />2 x 140CPU43412A or 140CPU53414B Interbus local rack |
| Rack type | Local | Power dissipation in W | 4 W |
| Local signalling | for communication with the Quantum CPU active (ACTIVE) 1 LED (green)<br /> for firmware and module run (RUN) 1 LED (green)<br /> for Interbus is functioning normally and carrying data (IS-B RUN) 1 LED (green)<br /> for fault module (F) 1 LED (red)<br /> for initialization fault with the DEA 202 1 LED (red)<br /> for Interbus master is not operational 1 LED (red)<br /> for Interbus module has reported a fault 1 LED (red)<br /> for memory fault 1 LED (red)<br /> for peripheral bus fault 1 LED (red)<br /> for processor fault (master) 1 LED (red)<br /> for remote bus fault 1 LED (red)<br /> for one or more bus segments are shut down 1 LED (yellow) | Electrical connection | 1 connector SUB-D 9<br />1 connector SUB-D 9 Interbus link |
| marking | CE | Net Weight | 2.0 lb(US) (0.9 kg) |
| Resistance to electrostatic discharge | 4 kV contact IEC 801-2<br />8 kV on air IEC 801-2 | Resistance to electromagnetic fields | 9.1 V/m (10 V/m) 80...1000 MHz IEC 801-3 |
| Ambient Air Temperature for Operation | 32…140 °F (0…60 °C) | Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
| Relative Humidity | 95 % without condensation | Operating altitude | <= 16404.2 ft (5000 m) |
| Product Certifications | CSA<br />UL |
Specifications may be subject to change without notice