ATV212HD55N4
Product ID:32538
Updated: 2026/4/5

Key Features
- 1Deliver 75 HP for demanding HVAC and industrial applications. 2、Integrate seamlessly with Modbus, BACnet, and other major protocols. 3、Reduce electromagnetic interference with an integrated Class C2 EMC filter. 4、Achieve precise motor control with adjustable 0.1-999.9s acceleration times. 5、Cut energy consumption by up to 70% with over 98% operational efficiency.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Device short name | ATV212 | Product destination | Asynchronous motors |
| Phase | 3 phase | Motor power kW | 55 kW |
| Maximum Horse Power Rating | 75 hp | Supply voltage limits | 323…528 V |
| Supply frequency | 50...60 Hz - 5...5 % | Line current | 102.7 A 380 V<br />89 A 480 V |
| Range of Product | Altivar 212 | Product or Component Type | Variable speed drive |
| Product Specific Application | Pumps and fans in HVAC | communication port protocol | METASYS N2<br />BACnet<br />LonWorks<br />APOGEE FLN<br />Modbus |
| [Us] rated supply voltage | 380...480 V - 15...10 % | EMC filter | Class C2 EMC filter integrated |
| IP degree of protection | IP20 on upper part without blanking plate on cover IEC 61800-5-1<br />IP20 on upper part without blanking plate on cover IEC 60529<br />IP21 IEC 61800-5-1<br />IP21 IEC 60529<br />IP41 on upper part IEC 61800-5-1<br />IP41 on upper part IEC 60529 | Apparent power | 76.3 kVA 380 V |
| Continuous output current | 116 A 380 V<br />116 A 460 V | Maximum transient current | 127.6 A 60 s |
| Speed drive output frequency | 0.5…200 Hz | Speed range | 1…10 |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn | Local signalling | for DC bus energized 1 LED (red) |
| Output voltage | <= power supply voltage | Isolation | Electrical between power and control |
| Type of cable | Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR<br />Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC<br />With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC | Electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14<br />L1/R, L2/S, L3/T terminal 0.2 in² (150 mm²) 300 kcmil) |
| Tightening torque | 5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)<br />362.9 lbf.in (41 N.m), 360 lb.in L1/R, L2/S, L3/T) | Supply | Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection<br />Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection |
| Sampling duration | 2 ms +/- 0.5 ms F discrete<br />2 ms +/- 0.5 ms R discrete<br />2 ms +/- 0.5 ms RES discrete<br />3.5 ms +/- 0.5 ms VIA analog<br />22 ms +/- 0.5 ms VIB analog | Response time | FM 2 ms +/- 0.5 ms analog<br />FLA, FLC 7 ms +/- 0.5 ms discrete<br />FLB, FLC 7 ms +/- 0.5 ms discrete<br />RY, RC 7 ms +/- 0.5 ms discrete |
| Accuracy | +/- 0.6 % VIA) for a temperature variation 60 °C<br />+/- 0.6 % VIB) for a temperature variation 60 °C<br />+/- 1 % FM) for a temperature variation 60 °C | Linearity error | VIA +/- 0.15 % of maximum value input<br />VIB +/- 0.15 % of maximum value input<br />FM +/- 0.2 % output |
| Analogue output type | FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits<br />FM switch-configurable current 0...20 mA 970 Ohm 10 bits | Discrete output type | Configurable relay logic FLA, FLC) NO - 100000 cycles<br />Configurable relay logic FLB, FLC) NC - 100000 cycles<br />Configurable relay logic RY, RC) NO - 100000 cycles |
| Minimum switching current | 3 mA 24 V DC configurable relay logic | Maximum switching current | 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)<br />5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)<br />2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R)<br />2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R) |
| Discrete input type | F programmable 24 V DC level 1 PLC 4700 Ohm<br />R programmable 24 V DC level 1 PLC 4700 Ohm<br />RES programmable 24 V DC level 1 PLC 4700 Ohm | Discrete input logic | Positive logic (source) F, R, RES), <= 5 V, >= 11 V<br />Negative logic (sink) F, R, RES), >= 16 V, <= 10 V |
| Dielectric strength | 3535 V DC between earth and power terminals<br />5092 V DC between control and power terminals | Insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
| Frequency resolution | Display unit 0.1 Hz<br />Analog input 0.024/50 Hz | Communication Service | Time out setting from 0.1 to 100 s<br />Write multiple registers (16) 2 words maximum<br />Write single register (06)<br />Read holding registers (03) 2 words maximum<br />Read device identification (43)<br />Monitoring inhibitable |
| Option card | Communication card LonWorks | Power dissipation in W | 1455 W |
| Air flow | 131560.04 Gal/hr(US) (498 m3/h) | Functionality | Mid |
| Specific application | HVAC | Variable speed drive application selection | Building - HVAC compressor for scroll<br />Building - HVAC fan<br />Building - HVAC pump |
| Motor power range AC-3 | 55…100 kW 380…440 V 3 phase<br />55…100 kW 480…500 V 3 phase | Motor starter type | Variable speed drive |
| Discrete output number | 2 | Analogue input number | 2 |
| Analogue input type | VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits<br />VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits<br />VIB configurable PTC probe 0...6 probes 1500 Ohm<br />VIA switch-configurable current 0...20 mA 250 Ohm 10 bits | Analogue output number | 1 |
| Physical interface | 2-wire RS 485 | Connector Type | 1 open style<br />1 RJ45 |
| Transmission Rate | 9600 bps or 19200 bps | Transmission frame | RTU |
| Number of addresses | 1…247 | Data format | 8 bits, 1 stop, odd even or no configurable parity |
| Type of polarization | No impedance | Asynchronous motor control profile | Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)<br />Flux vector control without sensor, standard<br />Voltage/frequency ratio, 5 points<br />Voltage/frequency ratio - Energy Saving, quadratic U/f<br />Voltage/frequency ratio, 2 points |
| Torque accuracy | +/- 15 % | Transient overtorque | 120 % of nominal motor torque +/- 10 % 60 s |
| Acceleration and deceleration ramps | Automatic based on the load<br />Linear adjustable separately from 0.01 to 3200 s | Motor slip compensation | Adjustable<br />Automatic whatever the load<br />Not available in voltage/frequency ratio motor control |
| Switching frequency | 6...16 kHz adjustable<br />8...16 kHz with derating factor | Nominal switching frequency | 8 kHz |
| Braking to standstill | By DC injection | Network Frequency | 47.5...63 Hz |
| Prospective line Isc | 22 kA | Protection type | Overheating protection drive<br />Thermal power stage drive<br />Short-circuit between motor phases drive<br />Input phase breaks drive<br />Overcurrent between output phases and earth drive<br />Overvoltages on the DC bus drive<br />Break on the control circuit drive<br />Against exceeding limit speed drive<br />Line supply overvoltage and undervoltage drive<br />Line supply undervoltage drive<br />Against input phase loss drive<br />Thermal protection motor<br />Motor phase break motor<br />With PTC probes motor |
| Width | 12.6 in (320 mm) | Height | 24.8 in (630 mm) |
| Depth | 11.4 in (290 mm) | Pollution degree | 3 IEC 61800-5-1 |
| Vibration resistance | 1.5 mm 3…13 Hz)IEC 60068-2-6<br />1 gn 13…200 Hz)EN/IEC 60068-2-8 | Shock resistance | 15 gn 11 ms IEC 60068-2-27 |
| Environmental characteristic | Classes 3C1 IEC 60721-3-3<br />Classes 3S2 IEC 60721-3-3 | Noise level | 63.7 dB 86/188/EEC |
| Operating altitude | 3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m<br /><= 3280.84 ft (1000 m) without derating | Relative humidity | 5…95 % without condensation IEC 60068-2-3<br />5…95 % without dripping water IEC 60068-2-3 |
| Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating)<br />104…122 °F (40…50 °C) with derating factor) | Operating position | Vertical +/- 10 degree |
| Product Certifications | C-tick<br />UL<br />CSA<br />NOM 117 | marking | CE |
| Standards | IEC 61800-3 environments 1 category C1<br />IEC 61800-3 environments 1 category C3<br />IEC 61800-5-1<br />IEC 61800-3<br />IEC 61800-3 environments 2 category C1<br />IEC 61800-3<br />IEC 61800-3 environments 1 category C2<br />EN 55011 class A group 1<br />IEC 61800-3 environments 1 category C1<br />IEC 61800-3 environments 2 category C3<br />IEC 61800-3 environments 1 category C2<br />IEC 61800-3 environments 2 category C3<br />IEC 61800-3 environments 2 category C2<br />UL Type 1<br />IEC 61800-3 category C2<br />IEC 61800-3 category C3<br />IEC 61800-5-1<br />EN 61800-3 category C3<br />IEC 61800-3 environments 2 category C2<br />IEC 61800-3 environments 1 category C3<br />IEC 61800-3 category C2<br />IEC 61800-3 environments 2 category C1 | Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6<br />Voltage dips and interruptions immunity test IEC 61000-4-11 | Regulation loop | Adjustable PI regulator |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Specifications may be subject to change without notice