ATV320D11M3C412
Product ID:35256
Updated: 2026/4/5

Key Features
- 1Achieve high power density for compact system designs. 2、Operate reliably across a wide temperature range. 3、Ensure low noise and high reliability for critical applications. 4、Utilize advanced protection features for enhanced safety. 5、Integrate seamlessly with various industrial control systems.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Altivar Solar | Product or Component Type | Variable speed drive |
| Product Specific Application | Pumping applications | Variant | Standard version |
| Format of the drive | Compact | Mounting Mode | Wall mount |
| communication port protocol | Modbus serial<br />CANopen | Option card | communication module, Ethernet IP/Modbus TCP |
| [Us] rated supply voltage | 200...240 V - 15...10 % | Nominal output current | 54.0 A |
| Motor power kW | 11 kW heavy duty | EMC filter | Without EMC filter |
| IP degree of protection | IP20 | Discrete input number | 7 |
| Discrete input type | STO safe torque off, 24 V DC1.5 kOhm<br />DI1...DI6 logic inputs, 24 V DC 30 V)<br />DI5 programmable as pulse input 0…30 kHz, 24 V DC 30 V) | Discrete input logic | Positive logic (source)<br />Negative logic (sink) |
| Discrete output number | 3 | Discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mA<br />Open collector DQ- 0…1 kHz 30 V DC 100 mA |
| Analogue input number | 3 | Analogue input type | AI1 voltage 0...10 V DC 30 kOhm 10 bits<br />AI2 bipolar differential voltage +/- 10 V DC 30 kOhm 10 bits<br />AI3 current 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration) 250 Ohm 10 bits |
| Analogue output number | 1 | Analogue output type | Software-configurable current AQ1 0...20 mA 800 Ohm 10 bits<br />Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits |
| Relay output number | 2 | Relay output type | Configurable relay logic R1A 1 NO 100000 cycles<br />Configurable relay logic R1B 1 NC 100000 cycles<br />Configurable relay logic R1C<br />Configurable relay logic R2A 1 NO 100000 cycles<br />Configurable relay logic R2C |
| Maximum switching current | Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 250 V AC<br />Relay output R1A, R1B, R1C resistive, cos phi = 1 3 A 30 V DC<br />Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC<br />Relay output R1A, R1B, R1C, R2A, R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC<br />Relay output R2A, R2C resistive, cos phi = 1 5 A 250 V AC<br />Relay output R2A, R2C resistive, cos phi = 1 5 A 30 V DC | Minimum switching current | Relay output R1A, R1B, R1C, R2A, R2C 5 mA 24 V DC |
| Method of access | Slave CANopen | Number of addresses | 1…247<br />1…127 |
| Data format | 8 bits, configurable odd, even or no parity | Type of polarization | No impedance |
| 4 quadrant operation possible | True | Asynchronous motor control profile | Voltage/frequency ratio, 5 points<br />Flux vector control without sensor, standard<br />Voltage/frequency ratio - Energy Saving, quadratic U/f<br />Flux vector control without sensor - Energy Saving<br />Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor | Transient overtorque | 170…200 % of nominal motor torque |
| Maximum output frequency | 0.599 kHz | Acceleration and deceleration ramps | Linear<br />U<br />S<br />CUS<br />Ramp switching<br />Acceleration/deceleration ramp adaptation<br />Acceleration/deceleration automatic stop with DC injection<br />Automatic adaptation of ramp if braking capacity exceeded, by using resistor<br />Linear adjustable separately from 0.01 to 6000 s |
| Motor slip compensation | Automatic whatever the load<br />Adjustable 0...300 %<br />Not available in voltage/frequency ratio (2 or 5 points) | Switching frequency | 2...16 kHz adjustable<br />4...16 kHz with derating factor |
| Nominal switching frequency | 4 kHz | Braking to standstill | By DC injection |
| Brake chopper integrated | True | Line current | 60.9 A 200 V heavy duty)<br />51.4 A 240 V heavy duty) |
| Maximum Input Current per Phase | 60.9 A | Maximum output voltage | 240 V |
| Apparent power | 21.4 kVA 240 V heavy duty) | Maximum transient current | 81.0 A 60 s |
| Short-circuit protection | thermal protection | Network Frequency | 50-60 Hz |
| Relative symmetric network frequency tolerance | 5 % | Prospective line Isc | 22 kA |
| Base load current at high overload | 1.5 A | Power dissipation in W | Fan 468.0 W 200 V 4 kHz |
| Electrical connection | Screw terminal 0.5...1.5 mm² analog input<br />Screw terminal analog output<br />Screw terminal | With safety function Safely Limited Speed (SLS) | True |
| With safety function Safe brake management (SBC/SBT) | False | With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False | With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False | With safety function Safe Stop 1 (SS1) | True |
| With sft fct Safe Stop 2 (SS2) | False | With safety function Safe torque off (STO) | True |
| With safety function Safely Limited Position (SLP) | False | With safety function Safe Direction (SDI) | False |
| Protection type | Input phase breaks drive<br />Overcurrent between output phases and earth drive<br />Overheating protection drive<br />Short-circuit between motor phases drive<br />Thermal protection drive | Width | 7.09 in (180 mm) |
| Height | 13.0 in (330 mm) | Depth | 7.8 in (198.0 mm) |
| Net Weight | 15.0 lb(US) (6.8 kg) | Power factor | 0.604 at 230 V |
| Braking torque | 170 % with braking resistor | Local signalling | for drive fault 1 LED (red)<br /> for CANopen error 1 LED (red)<br /> for CANopen run 1 LED (green) |
| Operating altitude | 3280.84...6561.68 ft (1000...2000 m) with current derating 1 % per 100 m<br /><= 3280.84 ft (1000 m) without derating | Operating position | Vertical +/- 10 degree |
| Product Certifications | CE<br />UR<br />UKCA<br />RCM | marking | CE<br />UR<br />UKCA<br />RCM |
| Standards | IEC 61800-5-1 | Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 IEC 61000-4-2<br />Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3<br />Electrical fast transient/burst immunity test level 4 IEC 61000-4-4<br />1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5<br />Conducted radio-frequency immunity test level 3 IEC 61000-4-6<br />Voltage dips and interruptions immunity test IEC 61000-4-11 | Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3<br />Class 3S2 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms | Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz | Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Volume of cooling air | 41211.6 Gal/hr(US) (156.0 m3/h) | Overvoltage category | II |
| Regulation loop | Adjustable PID regulator | Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| Noise level | 58 dB | Pollution degree | 2 |
| Ambient air transport temperature | -13…158 °F (-25…70 °C) | Ambient air temperature for operation | 14…122 °F (-10…50 °C) without derating<br />122…140 °F (50…60 °C) with derating factor |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Specifications may be subject to change without notice