GV2RT16
Product ID:29876
Updated: 2026/4/3

Key Features
- 1Deliver high-performance thermal-magnetic protection for reliable tripping. 2、Provide a 3-pole design suitable for balanced 3-phase system protection. 3、Handle currents up to 14A for versatile power applications. 4、Ensure global compliance with IEC, UL, CSA, CCC, EAC, and Marine standards. 5、Offer durable construction rated for 100,000 operational cycles.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | TeSys Deca | Product name | TeSys GV2 |
| Product or Component Type | Motor circuit breaker | Device short name | GV2RT |
| Device Application | Motor protection<br />Motor | Trip unit technology | Thermal-magnetic |
| Poles description | 3P | Network type | AC |
| Utilisation category | Category A IEC 60947-2<br />AC-3 IEC 60947-4-1<br />AC-3e IEC 60947-4-1 | Network frequency | 50/60 Hz IEC 60947-4-1 |
| Motor power kW | 2.2 kW 220/230 V AC 50/60 Hz motor protection high peak current<br />3 kW 220/230 V AC 50/60 Hz motor protection high peak current<br />5.5 kW 400/415 V AC 50/60 Hz motor protection high peak current<br />5.5 kW 440 V AC 50/60 Hz motor protection high peak current<br />7.5 kW 440 V AC 50/60 Hz motor protection high peak current<br />7.5 kW 500 V AC 50/60 Hz motor protection high peak current<br />9 kW 690 V AC 50/60 Hz motor protection high peak current<br />11 kW 690 V AC 50/60 Hz motor protection high peak current<br />4 kW 230/240 V AC 50/60 Hz transformer protection<br />6.3 kW 400/415 V AC 50/60 Hz transformer protection<br />6.3 kW 440 V AC 50/60 Hz transformer protection<br />10 kW 690 V AC 50/60 Hz transformer protection<br />12.5 kW 690 V AC 50/60 Hz transformer protection | Breaking capacity | 100 kA Icu 220/230 V AC 50/60 Hz IEC 60947-2<br />15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2<br />8 kA Icu 440 V AC 50/60 Hz IEC 60947-2<br />6 kA Icu 500 V AC 50/60 Hz IEC 60947-2<br />3 kA Icu 690 V AC 50/60 Hz IEC 60947-2 |
| Control Type | Toggle | Line Rated Current | 14 A |
| Thermal protection adjustment range | 9…14 A IEC 60947-4-1 | Magnetic tripping current | 280 A |
| [Ith] conventional free air thermal current | 14 A IEC 60947-4-1 | [Ue] rated operational voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz IEC 60947-2 | [Uimp] rated impulse withstand voltage | 6 kV IEC 60947-2 |
| Suitability for isolation | Yes IEC 60947-1 | Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles | Electrical durability | 100000 cycles AC-3 415 V In<br />100000 cycles AC-3e 415 V In |
| Rated duty | Continuous IEC 60947-4-1 | Tightening torque | 15.05 lbf.in (1.7 N.m) screw clamp terminal |
| Fixing mode | 35 mm symmetrical DIN rail clipped<br />Panel screwed with adaptor plate) | Mounting position | Horizontal<br />Vertical |
| Width | 1.8 in (45 mm) | Height | 3.5 in (89 mm) |
| Depth | 3.09 in (78.5 mm) | Standards | EN/IEC 60947-2<br />EN/IEC 60947-4-1 |
| Product Certifications | CCC<br />UL<br />CSA<br />EAC<br />LROS (Lloyds register of shipping)<br />BV<br />UKCA | IK degree of protection | IK04 |
| IP degree of protection | IP20 IEC 60529 | Climatic withstand | IACS E10 |
| Ambient Air Temperature for Storage | -40…176 °F (-40…80 °C) | Fire resistance | 1760 °F (960 °C) IEC 60695-2-11 |
| Ambient air temperature for operation | -4…140 °F (-20…60 °C) | Mechanical robustness | Shocks 30 Gn for 11 ms<br />Vibrations 5 Gn, 5...150 Hz |
| Operating altitude | 6561.68 ft (2000 m) |
Specifications may be subject to change without notice