LC1D099JL
Product ID:30760
Updated: 2026/4/3

Key Features
- 1Withstand extreme conditions with a long mechanical and electrical life. 2、Suit various industrial applications like manufacturing and HVAC systems. 3、Reduce operational costs through low power consumption. 4、Meet international safety standards IEC and VDE for compliance. 5、Integrate easily into panels with a compact design and screw terminals.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | TeSys | Range of Product | TeSys D |
| Product or Component Type | Contactor | Device short name | LC1D |
| Contactor application | Motor control<br />Resistive load | Utilisation category | AC-1<br />AC-3 |
| Poles description | 3P | [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz<br />Power circuit <= 300 V DC |
| [Ie] rated operational current | 9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit | [Uc] control circuit voltage | 12 V DC |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz<br />4 kW at 380...400 V AC 50/60 Hz<br />4 kW at 415...440 V AC 50/60 Hz<br />5.5 kW at 500 V AC 50/60 Hz<br />5.5 kW at 660...690 V AC 50/60 Hz | Maximum Horse Power Rating | 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors<br />2 hp at 200/208 V AC 50/60 Hz for 3 phase motors<br />2 hp at 230/240 V AC 50/60 Hz for 3 phase motors<br />5 hp at 460/480 V AC 50/60 Hz for 3 phase motors<br />7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors<br />0.33 hp at 115 V AC 50/60 Hz for 1 phase motors |
| compatibility code | LC1D | Pole contact composition | 3 NO |
| Protective cover | With | [Ith] conventional free air thermal current | 25 A (at 140 °F (60 °C)) for power circuit<br />10 A (at 140 °F (60 °C)) for signalling circuit |
| Irms rated making capacity | 250 A at 440 V for power circuit conforming to IEC 60947<br />140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1 | Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 105 A 104 °F (40 °C) - 10 s for power circuit<br />210 A 104 °F (40 °C) - 1 s for power circuit<br />30 A 104 °F (40 °C) - 10 min for power circuit<br />61 A 104 °F (40 °C) - 1 min for power circuit<br />100 A - 1 s for signalling circuit<br />120 A - 500 ms for signalling circuit<br />140 A - 100 ms for signalling circuit | Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1<br />25 A gG at <= 690 V coordination type 1 for power circuit<br />20 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit | Power dissipation per pole | 1.56 W AC-1<br />0.2 W AC-3 |
| [Ui] rated insulation voltage | Power circuit 690 V IEC 60947-4-1<br />Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Signalling circuit 690 V IEC 60947-1<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL | Overvoltage category | III |
| Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 30 Mcycles |
| Electrical durability | 0.6 Mcycles 25 A AC-1 <= 440 V<br />2 Mcycles 9 A AC-3 <= 440 V | Control circuit type | DC low consumption |
| Coil technology | Built-in bidirectional peak limiting diode suppressor | Control circuit voltage limits | 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC<br />0.8...1.25 Uc -40…140 °F (-40…60 °C) operational DC<br />1...1.25 Uc 140…158 °F (60…70 °C) operational DC |
| Inrush power in W | 2.4 W 68 °F (20 °C)) | Hold-in power consumption in W | 2.4 W 68 °F (20 °C) |
| Operating time | 65.45...88.55 ms closing<br />20...30 ms opening | Time constant | 40 ms |
| Maximum operating rate | 3600 cyc/h 140 °F (60 °C) | Connections - terminals | Power circuit: Faston terminals 2<br />Control circuit: Faston terminals 1 |
| Auxiliary contact composition | 1 NO + 1 NC | Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz | Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit | Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact | Mounting Support | Rail<br />Plate |
| Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508 | Product Certifications | LROS (Lloyds register of shipping)<br />UL<br />CSA<br />GOST<br />DNV<br />CCC<br />BV<br />RINA<br />GL |
| IP degree of protection | IP20 front face IEC 60529 | Protective treatment | THIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat<br /> IEC 60947-1 Annex Q category D exposure to damp heat | Permissible ambient air temperature around the device | -76…176 °F (-60…80 °C) storage<br />-40…140 °F (-40…60 °C) operation<br />140…158 °F (60…70 °C) with derating |
| Operating altitude | 0...9842.52 ft (0...3000 m) | Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 | Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor open 10 Gn for 11 ms) <br />Shocks contactor closed 15 Gn for 11 ms) |
| Height | 3.1 in (80 mm) | Width | 1.8 in (45 mm) |
| Depth | 3.7 in (95 mm) | Net Weight | 1.06 lb(US) (0.48 kg) |
Specifications may be subject to change without notice