LC1D150F7
Product ID:31128
Updated: 2026/4/4

Key Features
- 1Achieve high reliability with long mechanical and electrical life. 2、Reduce panel complexity and size with built-in auxiliary contacts. 3、Control motors rated for 110V and 150A operations efficiently. 4、Simplify installation with DIN rail and panel mounting compatibility. 5、Ensure global compliance with UL, CSA, GOST, CCC, and other certifications.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | TeSys | Range of Product | TeSys Deca |
| Product or Component Type | Contactor | Device short name | LC1D |
| Contactor application | Motor control<br />Resistive load | Utilisation category | AC-4<br />AC-3<br />AC-1<br />AC-3e |
| Poles description | 3P | [Ue] rated operational voltage | Power circuit <= 1000 V AC 25...400 Hz<br />Power circuit <= 300 V DC |
| [Ie] rated operational current | 200 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit<br />150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />150 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit | [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Motor power kW | 40 kW at 220...230 V AC 50/60 Hz (AC-3)<br />75 kW at 380...400 V AC 50/60 Hz (AC-3)<br />80 kW at 415...440 V AC 50/60 Hz (AC-3)<br />90 kW at 500 V AC 50/60 Hz (AC-3)<br />100 kW at 660...690 V AC 50/60 Hz (AC-3)<br />75 kW at 1000 V AC 50/60 Hz (AC-3)<br />22 kW at 400 V AC 50/60 Hz (AC-4)<br />40 kW at 220...230 V AC 50/60 Hz (AC-3e)<br />75 kW at 380...400 V AC 50/60 Hz (AC-3e)<br />80 kW at 415...440 V AC 50/60 Hz (AC-3e)<br />90 kW at 500 V AC 50/60 Hz (AC-3e)<br />100 kW at 660...690 V AC 50/60 Hz (AC-3e)<br />75 kW at 1000 V AC 50/60 Hz (AC-3e) | Maximum Horse Power Rating | 40 hp at 200/208 V AC 50/60 Hz for 3 phase motors<br />50 hp at 230/240 V AC 50/60 Hz for 3 phase motors<br />100 hp at 460/480 V AC 50/60 Hz for 3 phase motors<br />125 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| compatibility code | LC1D | Pole contact composition | 3 NO |
| Protective cover | With | [Ith] conventional free air thermal current | 200 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1<br />1660 A at 440 V for power circuit conforming to IEC 60947 | Rated breaking capacity | 1400 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 250 A 104 °F (40 °C) - 10 min for power circuit<br />580 A 104 °F (40 °C) - 1 min for power circuit<br />1200 A 104 °F (40 °C) - 10 s for power circuit<br />1400 A 104 °F (40 °C) - 1 s for power circuit<br />100 A - 1 s for signalling circuit<br />120 A - 500 ms for signalling circuit<br />140 A - 100 ms for signalling circuit | Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1<br />315 A gG at <= 690 V coordination type 1 for power circuit<br />250 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit | Power dissipation per pole | 24 W AC-1<br />13.5 W AC-3<br />13.5 W AC-3e |
| [Ui] rated insulation voltage | Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-1<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL | Overvoltage category | III |
| Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 8 Mcycles |
| Electrical durability | 0.85 Mcycles 150 A AC-3 <= 440 V<br />1 Mcycles 200 A AC-1 <= 440 V<br />0.85 Mcycles 150 A AC-3e <= 440 V | Control circuit type | AC 50/60 Hz standard |
| Coil technology | Built-in bidirectional peak limiting diode suppressor | Control circuit voltage limits | 0.3...0.5 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.15 Uc -40…131 °F (-40…55 °C) operational AC 50/60 Hz<br />1...1.15 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz |
| Inrush power in VA | 280…350 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C))<br />280…350 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C)) | Hold-in power consumption in VA | 2…18 VA 60 Hz cos phi 0.9 (at 68 °F (20 °C))<br />2…18 VA 50 Hz cos phi 0.9 (at 68 °F (20 °C)) |
| Heat dissipation | 3…4.5 W at 50/60 Hz | Operating time | 20...35 ms closing<br />40...75 ms opening |
| Maximum operating rate | 1200 cyc/h at 60 °C | Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible without cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: flexible with cable end<br />Power circuit: connector 1 0.02…0.2 in² (10…120 mm²) - cable stiffness: solid without cable end<br />Power circuit: connector 2 0.02…0.08 in² (10…50 mm²) - cable stiffness: solid without cable end |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2<br />Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)<br />Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 | Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1 | Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit | Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit | Non-overlap time | 1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact |
| Mounting Support | Plate<br />Rail | Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />IEC 60947-4-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1 |
| Product Certifications | UL<br />CCC<br />CSA<br />CE<br />UKCA<br />Marine<br />EAC | IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | THIEC 60068-2-30 | Climatic withstand | IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating | Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 | Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) <br />Shocks contactor closed 15 Gn for 11 ms) <br />Shocks contactor open 6 Gn for 11 ms) | Height | 6.2 in (158 mm) |
| Width | 4.7 in (120 mm) | Depth | 5.4 in (136 mm) |
| Net Weight | 5.5 lb(US) (2.5 kg) |
Specifications may be subject to change without notice