LC1D40008E7
Product ID:31477
Updated: 2026/4/4

Key Features
- 1Utilize a high-performance 4-pole configuration with 2NO-2NC contacts for reliable operation. 2、Employ a 48V AC coil for efficient and stable power management. 3、Support up to 60A maximum load current for diverse industrial applications. 4、Ensure optimal performance in resistive load applications across various environments. 5、Achieve long-term reliability with durable construction offering 1.4 million operating cycles.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | TeSys | Range of Product | TeSys Deca |
| Product or Component Type | Contactor | Device short name | LC1D |
| Contactor application | Resistive load | Utilisation category | AC-1 |
| Poles description | 4P | [Ue] rated operational voltage | Power circuit <= 690 V AC 25...400 Hz<br />Power circuit <= 300 V DC |
| [Ie] rated operational current | 60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit | [Uc] control circuit voltage | 48 V AC 50/60 Hz |
| Compatibility code | LC1D | Pole contact composition | 2 NO + 2 NC |
| Protective cover | With | [Ith] conventional free air thermal current | 60 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 800 A at 440 V for power circuit conforming to IEC 60947 | Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 320 A 104 °F (40 °C) - 10 s for power circuit<br />720 A 104 °F (40 °C) - 1 s for power circuit<br />72 A 104 °F (40 °C) - 10 min for power circuit<br />165 A 104 °F (40 °C) - 1 min for power circuit | Associated fuse rating | 80 A gG at <= 690 V coordination type 1 for power circuit<br />80 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 1.5 mOhm - Ith 60 A 50 Hz for power circuit | Power dissipation per pole | 5.4 W AC-1 |
| [Ui] rated insulation voltage | Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 690 V IEC 60947-4-1 | Overvoltage category | III |
| Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 6 Mcycles |
| Electrical durability | 1.4 Mcycles 60 A AC-1 <= 440 V | Control circuit type | AC 50/60 Hz |
| Coil technology | Without built-in suppressor module | Control circuit voltage limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz<br />0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz<br />0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz<br />1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz |
| Inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))<br />160 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) | Hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))<br />15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) |
| Heat dissipation | 4…5 W at 50/60 Hz | Operating time | 4...19 ms opening<br />12...26 ms closing |
| Maximum operating rate | 3600 cyc/h at 60 °C | Connections - terminals | Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end<br />Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end<br />Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible without cable end<br />Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end<br />Power circuit: screw connection 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid without cable end<br />Power circuit: screw connection 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: solid without cable end |
| Tightening torque | Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2<br />Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm)<br />Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.002…0.04 in² (1…25 mm²) hexagonal 0.2 in (4 mm)<br />Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 | Mounting Support | Rail<br />Plate |
| Standards | CSA C22.2 No 14<br />EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />UL 508 | Product Certifications | CCC<br />CSA<br />BV<br />UL<br />DNV<br />RINA<br />LROS (Lloyds register of shipping)<br />GOST<br />GL |
| IP degree of protection | IP20 front face IEC 60529 | Protective treatment | THIEC 60068-2-30 |
| Climatic withstand | IACS E10 exposure to damp heat | Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating |
| Operating altitude | 0...9842.52 ft (0...3000 m) | Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 | Mechanical robustness | Shocks contactor open 8 Gn for 11 ms) <br />Shocks contactor closed 10 Gn for 11 ms) <br />Vibrations contactor opened 2 Gn, 5...300 Hz) <br />Vibrations contactor closed 4 Gn, 5...300 Hz) |
| Height | 5.0000000000 in (127 mm) | Width | 3.3 in (85 mm) |
| Depth | 4.9 in (125 mm) | Net Weight | 3.17 lb(US) (1.44 kg) |
Specifications may be subject to change without notice