LC1D806BD
Product ID:32206
Updated: 2026/4/6

Key Features
- 1Control motors reliably with a high 80A AC-3 current rating. 2、Install easily using versatile DIN rail or panel mounting options. 3、Simplify circuit logic with built-in NO+NC auxiliary contacts. 4、Operate with flexibility using 24V DC or up to 300V DC coils. 5、Ensure global compliance with UL, CSA, IEC, CCC, EAC, and Marine certifications.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | TeSys | Range of Product | TeSys Deca |
| Product or Component Type | Contactor | Device short name | LC1D |
| Contactor application | Resistive load<br />Motor control | Utilisation category | AC-3<br />AC-3e<br />AC-4<br />AC-1 |
| Poles description | 3P | [Ue] rated operational voltage | Power circuit <= 300 V DC 25...400 Hz<br />Power circuit <= 690 V AC |
| [Ie] rated operational current | 125 A (at <140 °F (60 °C)) at <= 1000 V AC AC-1 for power circuit<br />80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit | [Uc] control circuit voltage | 24 V DC |
| Motor power kW | 22 kW at 220...230 V AC 50/60 Hz (AC-3)<br />37 kW at 380...400 V AC 50/60 Hz (AC-3)<br />45 kW at 415...440 V AC 50/60 Hz (AC-3)<br />55 kW at 500 V AC 50/60 Hz (AC-3)<br />45 kW at 660...690 V AC 50/60 Hz (AC-3)<br />15 kW at 400 V AC 50/60 Hz (AC-4)<br />22 kW at 220...230 V AC 50/60 Hz (AC-3e)<br />37 kW at 380...400 V AC 50/60 Hz (AC-3e)<br />45 kW at 415...440 V AC 50/60 Hz (AC-3e)<br />55 kW at 500 V AC 50/60 Hz (AC-3e)<br />45 kW at 660...690 V AC 50/60 Hz (AC-3e) | Maximum Horse Power Rating | 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors<br />15 hp at 230/240 V AC 50/60 Hz for 1 phase motors<br />30 hp at 200/208 V AC 50/60 Hz for 3 phase motors<br />30 hp at 230/240 V AC 50/60 Hz for 3 phase motors<br />60 hp at 460/480 V AC 50/60 Hz for 3 phase motors<br />60 hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Compatibility code | LC1D | Pole contact composition | 3 NO |
| Protective cover | With | [Ith] conventional free air thermal current | 10 A (at 140 °F (60 °C)) for signalling circuit<br />125 A (at 140 °F (60 °C)) for power circuit |
| Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1<br />250 A DC for signalling circuit conforming to IEC 60947-5-1<br />1100 A at 440 V for power circuit conforming to IEC 60947 | Rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 640 A 104 °F (40 °C) - 10 s for power circuit<br />990 A 104 °F (40 °C) - 1 s for power circuit<br />135 A 104 °F (40 °C) - 10 min for power circuit<br />320 A 104 °F (40 °C) - 1 min for power circuit<br />100 A - 1 s for signalling circuit<br />120 A - 500 ms for signalling circuit<br />140 A - 100 ms for signalling circuit | Associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1<br />200 A gG at <= 690 V coordination type 1 for power circuit<br />160 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit | Power dissipation per pole | 5.1 W AC-3<br />12.5 W AC-1<br />5.1 W AC-3e |
| [Ui] rated insulation voltage | Power circuit 600 V CSA<br />Power circuit 600 V UL<br />Power circuit 1000 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-1<br />Signalling circuit 600 V CSA<br />Signalling circuit 600 V UL | Overvoltage category | III |
| Pollution degree | 3 | [Uimp] rated impulse withstand voltage | 8 kV IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 10 Mcycles |
| Electrical durability | 0.8 Mcycles 125 A AC-1 <= 440 V<br />1.5 Mcycles 80 A AC-3 <= 440 V<br />1.5 Mcycles 80 A AC-3e <= 440 V | Control circuit type | DC standard |
| Coil technology | Without built-in suppressor module | Control circuit voltage limits | 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC<br />0.85...1.1 Uc -40…131 °F (-40…55 °C) operational DC<br />1...1.1 Uc 131…158 °F (55…70 °C) operational DC |
| Inrush power in W | 22 W 68 °F (20 °C)) | Hold-in power consumption in W | 22 W 68 °F (20 °C) |
| Operating time | 95...130 ms closing<br />20...35 ms opening | Time constant | 75 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C | Connections - terminals | Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm)<br />Power circuit: bars 1 - busbar cross section: 3 x 16 mm<br />Power circuit: lugs-ring terminals - external diameter: 0.7 in (17 mm) |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals flat Ø 6 mm M3.5<br />Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals Philips No 2 M3.5<br />Power circuit 44.3 lbf.in (5 N.m) lugs-ring terminals flat Ø 8 mm M6<br />Power circuit 44.3 lbf.in (5 N.m) lugs-ring terminals hexagonal 0.4 in (10 mm) M6<br />Power circuit 44.3 lbf.in (5 N.m) bars flat Ø 8 mm M6<br />Power circuit 44.3 lbf.in (5 N.m) bars hexagonal 0.4 in (10 mm) M6<br />Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals pozidriv No 2 M3.5 | Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | Mechanically linked 1 NO + 1 NC IEC 60947-5-1<br />Mirror contact 1 NC IEC 60947-4-1 | Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit | Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit | Non-overlap time | 1.5 ms on de-energisation between NC and NO contact<br />1.5 ms on energisation between NC and NO contact |
| Mounting Support | Rail<br />Plate | Standards | EN 60947-4-1<br />EN 60947-5-1<br />IEC 60947-4-1<br />IEC 60947-5-1<br />CSA C22.2 No 14<br />UL 60947-4-1<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ<br />IEC 60335-1:Clause 30.2 |
| Product Certifications | CCC<br />UL<br />CB Scheme<br />CSA<br />CE<br />UKCA<br />Marine<br />EAC | IP degree of protection | IP20 front face IEC 60529 |
| Protective treatment | THIEC 60068-2-30 | Climatic withstand | IACS E10 exposure to damp heat |
| Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C)<br />140…158 °F (60…70 °C) with derating | Operating altitude | 0...9842.52 ft (0...3000 m) |
| Fire resistance | 1562 °F (850 °C) IEC 60695-2-1 | Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open 2 Gn, 5...300 Hz) <br />Shocks contactor open 8 Gn for 11 ms) <br />Vibrations contactor closed 3 Gn, 5...300 Hz) <br />Shocks contactor closed 10 Gn for 11 ms) | Height | 5.0000000000 in (127 mm) |
| Width | 3.3 in (85 mm) | Depth | 7.3 in (186 mm) |
| Net Weight | 5.71 lb(US) (2.59 kg) |
Specifications may be subject to change without notice