LC1F1154G6L
Product ID:32676
Updated: 2026/4/5

Key Features
- 1Deliver high current rating up to 115 A at 600 V AC. 2、Ensure reliable operation in harsh industrial environments. 3、Control with versatile 120 VAC 60 Hz coil compatibility. 4、Withstand high thermal currents and frequent switching. 5、Meet IEC and VDE standards for safety and performance.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | TeSys F | Product or Component Type | Contactor |
| Device short name | LC1F | Contactor application | Resistive load |
| Utilisation category | AC-1 | Poles description | 4P |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz<br /> <= 460 V DC | [Uc] control circuit voltage | 120 V AC 60 Hz |
| [Ie] rated operational current | 200 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 | [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 200 A (at 104 °F (40 °C)) | Rated breaking capacity | 920 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 1100 A 104 °F (40 °C) - 10 s<br />640 A 104 °F (40 °C) - 30 s<br />520 A 104 °F (40 °C) - 1 min<br />400 A 104 °F (40 °C) - 3 min<br />320 A 104 °F (40 °C) - 10 min | Associated fuse rating | 125 A aM at <= 440 V<br />200 A gG at <= 440 V |
| [Ui] rated insulation voltage | 1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C | Power dissipation per pole | 15 W AC-1 |
| Overvoltage category | III | power pole contact composition | 4 NO |
| motor power HP (UL / CSA) | 30 hp at 200 V AC<br />40 hp at 230 V AC<br />75 hp at 460 V AC<br />100 hp at 575 V AC | Control circuit voltage limits | Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))<br />Drop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) |
| Mechanical durability | 10 Mcycles | Inrush power in VA | 660 VA, 60 Hz 0.3 68 °F (20 °C)) |
| Maximum operating rate | 2400 cyc/h 131 °F (55 °C) | Operating time | 23...35 ms closing<br />5...15 ms opening |
| Connections - terminals | Power circuit 2 bars 20 x 3 mm<br />Power circuit lugs-ring terminals 1 0.1 in² (95 mm²)<br />Power circuit connector 1 0.1 in² (95 mm²)<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bolted connection | Tightening torque | Power circuit 88.5 lbf.in (10 N.m)<br />Control circuit 10.6 lbf.in (1.2 N.m) |
| Mounting Support | Plate | Heat dissipation | 12…16 W |
| Standards | EN 60947-1<br />IEC 60947-1<br />IEC 60947-4-1<br />JIS C8201-4-1<br />EN 60947-4-1 | Product Certifications | BV<br />ABS<br />RINA<br />CB<br />CCC<br />RMRoS<br />UL<br />DNV<br />LROS (Lloyds register of shipping) |
| Hold-in power consumption in VA | 55 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) | IP degree of protection | IP2X front face with shrouds IEC 60529<br />IP2X front face with shrouds VDE 0106 |
| Protective treatment | TH | Ambient Air Temperature for Operation | -40…140 °F (-40…60 °C) |
| Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) | Permissible ambient air temperature around the device | 140…158 °F (60…70 °C) at Uc |
| Mechanical robustness | Vibrations contactor open2 Gn, 5...300 Hz<br />Vibrations contactor closed6 Gn, 5...300 Hz<br />Shocks contactor open9 Gn for 11 ms<br />Shocks contactor closed15 Gn for 11 ms | Height | 10.4 in (265 mm) |
| Width | 7.9 in (200.5 mm) | Depth | 6.7 in (171 mm) |
| Operating altitude | 9842.52 ft (3000 m) without derating |
Specifications may be subject to change without notice