LC1F4002FD
Product ID:32965
Updated: 2026/4/4

Key Features
- 1Control motors reliably up to 400A and 600VAC. 2、Ensure safety with IEC 60947-4-1 and EN 60947-4-1 compliance. 3、Integrate easily using the optional 110V DC coil. 4、Withstand harsh conditions with high vibration and shock resistance. 5、Meet sustainability goals with RoHS and Green Premium status.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | TeSys | Range of Product | TeSys F |
| Product or Component Type | Contactor | Device short name | LC1F |
| Contactor application | Resistive load | Utilisation category | AC-1 |
| Poles description | 2P | [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz<br /><= 460 V DC |
| [Uc] control circuit voltage | 110 V DC | [Ie] rated operational current | 500 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 |
| [Uimp] rated impulse withstand voltage | 8 kV | [Ith] conventional free air thermal current | 500 A (at 104 °F (40 °C)) |
| Rated breaking capacity | 3200 A conforming to IEC 60947-4-1 | [Icw] rated short-time withstand current | 3600 A 104 °F (40 °C) - 10 s<br />2400 A 104 °F (40 °C) - 30 s<br />1700 A 104 °F (40 °C) - 1 min<br />1200 A 104 °F (40 °C) - 3 min<br />1000 A 104 °F (40 °C) - 10 min |
| Associated fuse rating | 400 A aM at <= 440 V<br />500 A gG at <= 440 V | Average impedance | 0.26 mOhm - Ith 500 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C | Power dissipation per pole | 65 W AC-1 |
| Overvoltage category | III | power pole contact composition | 2 NO |
| Control circuit voltage limits | Operational 0.85...1.1 Uc 131 °F (55 °C))<br />Drop-out 0.2...0.35 Uc 131 °F (55 °C)) | Mechanical durability | 10 Mcycles |
| Inrush power in W | 1000 W 68 °F (20 °C)) | Hold-in power consumption in W | 6 W 68 °F (20 °C) |
| Maximum operating rate | 2400 cyc/h 131 °F (55 °C) | Operating time | 50...60 ms closing<br />45...60 ms opening |
| Connections - terminals | Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 30 x 5 mm<br />Power circuit lugs-ring terminals 2 0.2 in² (150 mm²)<br />Power circuit bolted connection | Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m) |
| Mounting Support | Plate | Heat dissipation | 6 W |
| Standards | EN 60947-1<br />EN 60947-4-1<br />IEC 60947-4-1<br />JIS C8201-4-1<br />IEC 60947-1 | Product Certifications | UL<br />RINA<br />RMRoS<br />CCC<br />ABS<br />CB<br />LROS (Lloyds register of shipping)<br />DNV<br />BV |
| compatibility code | LC1F | Control circuit type | DC standard |
| IP degree of protection | IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106 | Protective treatment | TH |
| Ambient Air Temperature for Operation | 23…131 °F (-5…55 °C) | Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
| Permissible ambient air temperature around the device | -40…158 °F (-40…70 °C) | Height | 8.1 in (206 mm) |
| Width | 8.4 in (213 mm) | Depth | 8.6 in (219 mm) |
| Operating altitude | 9842.52 ft (3000 m) without derating | Net Weight | 17.6 lb(US) (8 kg) |
Specifications may be subject to change without notice