Key Features

  • 1Handle high-power loads with a 500A AC-3 rated current.
  • 2Control motors up to 250kW@400V using a 3-pole configuration.
  • 3Operate reliably in Direct On Line (DOL) and FVNR applications.
  • 4Ensure global project compliance with IEC, UL, CSA, CCC, EAC, and Marine certifications.
  • 5Simplify installation and maintenance via bolt terminals and a coil selection drawer.

Need price and lead time?

Request a quote for original schneider LC1F500F722L. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original schneider
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
TeSys F
Product or Component Type
Contactor
Device short name
LC1F
Contactor application
Resistive load<br />Motor control
Utilisation category
AC-1<br />AC-4<br />AC-3
Poles description
3P
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz<br /> <= 460 V DC
[Uc] control circuit voltage
110 V AC 40...400 Hz
[Ie] rated operational current
700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1<br />500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
700 A (at 104 °F (40 °C))
Rated breaking capacity
4000 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
4200 A 104 °F (40 °C) - 10 s<br />3200 A 104 °F (40 °C) - 30 s<br />2400 A 104 °F (40 °C) - 1 min<br />1500 A 104 °F (40 °C) - 3 min<br />1200 A 104 °F (40 °C) - 10 min
Associated fuse rating
500 A aM at <= 440 V<br />800 A gG at <= 440 V
Average impedance
0.18 mOhm - Ith 700 A 50 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C
Overvoltage category
III
power pole contact composition
3 NO
Auxiliary contact composition
2 NO + 2 NC
Motor power kW
250 kW at 380...400 V AC 50/60 Hz (AC-3)<br />280 kW at 415 V AC 50/60 Hz (AC-3)<br />295 kW at 440 V AC 50/60 Hz (AC-3)<br />355 kW at 500 V AC 50/60 Hz (AC-3)<br />335 kW at 660...690 V AC 50/60 Hz (AC-3)<br />335 kW at 1000 V AC 50/60 Hz (AC-3)<br />147 kW at 220...230 V AC 50/60 Hz (AC-3)<br />80 kW at 400 V AC 50/60 Hz (AC-4)
motor power HP (UL / CSA)
150 hp at 200 V AC<br />200 hp at 230 V AC<br />400 hp at 460 V AC<br />500 hp at 575 V AC
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C))<br />Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bolted connection<br />Power circuit 2 bars 40 x 5 mm<br />Power circuit lugs-ring terminals 2 0.4 in² (240 mm²)
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m)
Mounting Support
Plate
Heat dissipation
18 W
Standards
IEC 60947-4-1<br />EN 60947-4-1<br />EN 60947-1<br />IEC 60947-1<br />JIS C8201-4-1
Product Certifications
CB<br />CSA<br />RMRoS<br />ABS<br />BV<br />LROS (Lloyds register of shipping)<br />UL<br />RINA<br />DNV
Hold-in power consumption in VA
18 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))
IP degree of protection
IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106
Protective treatment
TH
Ambient Air Temperature for Operation
23…131 °F (-5…55 °C)
Ambient Air Temperature for Storage
-76…176 °F (-60…80 °C)
Permissible ambient air temperature around the device
-40…158 °F (-40…70 °C)
Mechanical robustness
Vibrations contactor open2 Gn, 5...300 Hz<br />Shocks contactor open9 Gn for 11 ms<br />Shocks contactor closed15 Gn for 11 ms<br />Vibrations contactor closed4 Gn, 5...300 Hz
Height
15.7 in (400 mm)
Width
9.2 in (233 mm)
Depth
9.1 in (232 mm)

Specifications may be subject to change without notice