LC1K06017F72
Product ID:38272
Updated: 2026/4/3

Key Features
- 1Mount compactly on DIN-rails or panels. 2、Ensure compatibility with 50Hz and 60Hz power supplies. 3、Utilize the included 1NC auxiliary contact for control. 4、Handle high inrush power up to 30 VA reliably. 5、Meet IEC 60947-4-1 standards for safety.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | TeSys K | Range | TeSys |
| Product name | TeSys K | Device Application | Control |
| Product or Component Type | Contactor | Device short name | LC1K |
| Utilisation category | AC-4<br />AC-3 | Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Poles description | 3P | Pole contact composition | 3 NO |
| [Ie] rated operational current | 6 A at <= 440 V AC AC-3 for power circuit | [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Signalling circuit frequency | <= 400 Hz | Non overlap distance | 0.02 in (0.5 mm) |
| Contactor application | Motor control | Auxiliary contact composition | 1 NC |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C))<br />Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C)) | Control circuit type | AC 50/60 Hz |
| Connections - terminals | Faston terminals 2 2.8 mm<br /> Faston terminals 1 6.35 mm | Electrical durability | 1.3 Mcycles 6 A AC-3 <= 440 V |
| Mechanical robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27<br />Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6<br />Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 | Standards | EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1 |
| IP degree of protection | IP2X VDE 0106 | Protective treatment | TC IEC 60068<br />TC DIN 50016 |
| [Ui] rated insulation voltage | Power circuit 600 V UL 508<br />Power circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-5-1<br />Signalling circuit 600 V UL 508<br />Power circuit 600 V CSA C22.2 No 14<br />Signalling circuit 600 V CSA C22.2 No 14 | [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III | Mounting Support | Rail<br />Plate |
| Product Certifications | CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA | Ambient Air Temperature for Storage | -58…176 °F (-50…80 °C) |
| Operating altitude | 6561.68 ft (2000 m) without derating | [Ue] rated operational voltage | Power circuit 690 V AC 50/60 Hz<br />Signalling circuit <= 690 V AC 50/60 Hz |
| [Ith] conventional free air thermal current | 20 A (at 122 °F (50 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit | Irms rated making capacity | 110 A AC for power circuit conforming to NF C 63-110<br />110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947 | Associated fuse rating | 25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947<br />10 A gG for signalling circuit conforming to VDE 0660 |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit | Inrush power in VA | 30 VA (at 68 °F (20 °C)) |
| Hold-in power consumption in VA | 4.5 VA (at 68 °F (20 °C)) | Operating time | 10...20 ms coil de-energisation and NO opening<br />10...20 ms coil energisation and NO closing |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 | Mechanical durability | 10 Mcycles |
| Maximum operating rate | 3600 cyc/h | Minimum switching current | 5 mA for signalling circuit |
| Minimum switching voltage | 17 V for signalling circuit | Insulation resistance | > 10 MOhm for signalling circuit |
| Height | 2.3 in (58 mm) | Width | 1.8 in (45 mm) |
| Depth | 2.2 in (57 mm) | Net Weight | 0.40 lb(US) (0.18 kg) |
| compatibility code | LC1K | Motor power kW | 1.5 kW 220...230 V AC 50/60 Hz<br />2.2 kW 380...415 V AC 50/60 Hz<br />3 kW 440 V AC 50/60 Hz<br />3 kW 480 V AC 50/60 Hz<br />3 kW 500...600 V AC 50/60 Hz<br />3 kW 660...690 V AC 50/60 Hz |
| [Icw] rated short-time withstand current | 90 A 122 °F (50 °C) - 1 s for power circuit<br />85 A 122 °F (50 °C) - 5 s for power circuit<br />80 A 122 °F (50 °C) - 10 s for power circuit<br />60 A 122 °F (50 °C) - 30 s for power circuit<br />45 A 122 °F (50 °C) - 1 min for power circuit<br />40 A 122 °F (50 °C) - 3 min for power circuit<br />20 A 122 °F (50 °C) - >= 15 min for power circuit<br />80 A - 1 s for signalling circuit<br />90 A - 500 ms for signalling circuit<br />110 A - 100 ms for signalling circuit | Heat dissipation | 1.3 W |
| Flame retardance | V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102 |
Specifications may be subject to change without notice