LC1K0601B7
Product ID:38275
Updated: 2026/4/3

Key Features
- 1Control motors reliably with 3600 cycles per hour operation. 2、Save panel space using the compact 45mm wide design. 3、Reduce energy consumption via compatibility with PLC outputs. 4、Ensure versatile application with 50/60 Hz supply compatibility. 5、Add control flexibility with the included 1NC auxiliary contact.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range | TeSys | Product or Component Type | Contactor |
| Device short name | LC1K | Device Application | Control |
| Contactor application | Motor control | Utilisation category | AC-3<br />AC-3e<br />AC-4 |
| Poles description | 3P | power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit <= 690 V AC <= 400 Hz<br />Signalling circuit <= 690 V AC <= 400 Hz | [Ie] rated operational current | 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit<br />6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit |
| Control circuit type | AC 50/60 Hz | [Uc] control circuit voltage | 24 V AC 50/60 Hz |
| Motor power kW | 1.5 kW 220...230 V AC 50/60 Hz AC-3<br />2.2 kW 380...415 V AC 50/60 Hz AC-3<br />3 kW 440/690 V AC 50/60 Hz AC-3<br />1.5 kW 220...230 V AC 50/60 Hz AC-3e<br />2.2 kW 380...415 V AC 50/60 Hz AC-3e<br />3 kW 440/690 V AC 50/60 Hz AC-3e<br />1.5 kW 220...230 V AC 50/60 Hz AC-4<br />2.2 kW 380...415 V AC 50/60 Hz AC-4<br />3 kW 440/690 V AC 50/60 Hz AC-4 | Auxiliary contact composition | 1 NC |
| [Uimp] rated impulse withstand voltage | 8 kV | Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 140 °F (60 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit | Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947<br />110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947 | [Icw] rated short-time withstand current | 90 A 122 °F (50 °C) - 1 s for power circuit<br />85 A 122 °F (50 °C) - 5 s for power circuit<br />80 A 122 °F (50 °C) - 10 s for power circuit<br />60 A 122 °F (50 °C) - 30 s for power circuit<br />45 A 122 °F (50 °C) - 1 min for power circuit<br />40 A 122 °F (50 °C) - 3 min for power circuit<br />20 A 122 °F (50 °C) - >= 15 min for power circuit<br />80 A - 1 s for signalling circuit<br />90 A - 500 ms for signalling circuit<br />110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at <= 440 V for power circuit<br />25 A aM for power circuit<br />10 A gG for signalling circuit conforming to IEC 60947<br />10 A gG for signalling circuit conforming to VDE 0660 | Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit 600 V UL 508<br />Power circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-4-1<br />Signalling circuit 690 V IEC 60947-5-1<br />Signalling circuit 600 V UL 508<br />Power circuit 600 V CSA C22.2 No 14<br />Signalling circuit 600 V CSA C22.2 No 14 | Insulation resistance | > 10 MOhm for signalling circuit |
| Inrush power in VA | 30 VA (at 68 °F (20 °C)) | Hold-in power consumption in VA | 4.5 VA (at 68 °F (20 °C)) |
| Heat dissipation | 1.3 W | Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C))<br />Drop-out: >= 0.20 Uc (at <122 °F (50 °C)) |
| Connections - terminals | screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end<br /> screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end | Maximum operating rate | 3600 cyc/h |
| Auxiliary contacts type | Instantaneous 1 NC | Signalling circuit frequency | <= 400 Hz |
| Minimum switching current | 5 mA for signalling circuit | Minimum switching voltage | 17 V for signalling circuit |
| Mounting Support | Plate<br />Rail | Tightening torque | 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2<br /> 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm<br />Power circuit 7.08…11.5 lbf.in (0.8…1.3 N.m) lugs-ring terminals pozidriv No 2 |
| Operating time | 10...20 ms coil de-energisation and NO opening<br />10...20 ms coil energisation and NO closing | Safety reliability level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Non overlap distance | 0.02 in (0.5 mm) | Mechanical durability | 10 Mcycles |
| Electrical durability | 1.3 Mcycles 6 A AC-3 <= 440 V<br />1.3 Mcycles 6 A AC-3e <= 440 V<br />0.05 Mcycles 36 A AC-4 <= 440 V | Mechanical robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27<br />Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27<br />Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6<br />Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 |
| Height | 2.3 in (58 mm) | Width | 1.8 in (45 mm) |
| Depth | 2.2 in (57 mm) | Net Weight | 0.40 lb(US) (0.18 kg) |
| Standards | EN/IEC 60947-4-1<br />GB/T 14048.4<br />UL 60947-4-1<br />CSA C22.2 No 60947-4-1<br />JIS C8201-4-1<br />IEC 60335-1:Clause 30.2<br />IEC 60335-2-40:Annex JJ<br />UL 60335-2-40:Annex JJ | Product Certifications | CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA |
| IP degree of protection | IP2X VDE 0106 | Protective treatment | TC IEC 60068<br />TC DIN 50016 |
| Ambient Air Temperature for Storage | -58…176 °F (-50…80 °C) | Operating altitude | 6561.68 ft (2000 m) without derating |
| Flame retardance | V1 conforming to UL 94<br />Requirement 2 conforming to NF F 16-101<br />Requirement 2 conforming to NF F 16-102 |
Specifications may be subject to change without notice