LC7K09004M7TQ

Product ID:33221
Updated: 2026/7/15
schneider LC7K09004M7TQ

Key Features

  • 1Select components to meet or exceed desired SCCR.
  • 2Operate reliably in noise-sensitive and high-interference areas.
  • 3Ensure reliable switching with four normally open contacts.
  • 4Mount easily on 35 mm DIN rail or panel with screws.
  • 5Meet safety standards with IP2X enclosure and finger-safe terminals.

Need price and lead time?

Request a quote for original schneider LC7K09004M7TQ. Tell us your required quantity.

It only takes 1 minute — get your quotation and delivery time.
Quote within 24h
100% Original schneider
Global Delivery
No Spam · Secure

Need a quote? Enter your quantity and get pricing fast.

Qty

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Product or Component Type
Silent contactor
Device short name
LC7K
Contactor application
Resistive load
Utilisation category
AC-1
Poles description
4P
power pole contact composition
4 NO
[Ue] rated operational voltage
Power circuit <= 690 V AC <= 400 Hz<br />Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current
20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type
AC 50/60 Hz standard
[Uc] control circuit voltage
220 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
20 A (at 140 °F (60 °C)) for power circuit<br />10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to IEC 60947
Rated breaking capacity
110 A at 220...230 V conforming to IEC 60947<br />110 A at 380...400 V conforming to IEC 60947<br />110 A at 415 V conforming to IEC 60947<br />110 A at 440 V conforming to IEC 60947<br />80 A at 500 V conforming to IEC 60947<br />70 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current
90 A 122 °F (50 °C) - 1 s for power circuit<br />85 A 122 °F (50 °C) - 5 s for power circuit<br />80 A 122 °F (50 °C) - 10 s for power circuit<br />60 A 122 °F (50 °C) - 30 s for power circuit<br />45 A 122 °F (50 °C) - 1 min for power circuit<br />40 A 122 °F (50 °C) - 3 min for power circuit<br />20 A 122 °F (50 °C) - >= 15 min for power circuit
Associated fuse rating
10 A gG for control circuit conforming to IEC 60947<br />10 A gG for control circuit conforming to VDE 0660<br />25 A gG at <= 440 V for power circuit
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage
Control circuit 690 V BS 5424<br />Control circuit 690 V IEC 60947<br />Power circuit 690 V BS 5424<br />Power circuit 690 V IEC 60947<br />Power circuit 690 V NF C 20-040<br />Control circuit 750 V VDE 0110 group C<br />Power circuit 750 V VDE 0110 group C<br />Control circuit 600 V CSA C22.2 No 14<br />Power circuit 600 V UL 508 CSA C22.2 No 14
Insulation resistance
> 10 MOhm for control circuit
Inrush power in VA
3 VA (at 68 °F (20 °C))
Hold-in power consumption in VA
3 VA 50/60 Hz (at 68 °F (20 °C))
Control circuit voltage limits
Operational: 0.85...1.1 Uc at 50/60 Hz (at <122 °F (50 °C))<br />Drop-out: >= 0.10 Uc at 50/60 Hz (at <122 °F (50 °C))
Connections - terminals
screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end<br /> screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid<br /> screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end<br /> screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Maximum operating rate
3600 cyc/h
Coil technology
Built-in bidirectional peak limiting diode suppressor
Minimum switching current
5 mA for control circuit
Minimum switching voltage
17 V for control circuit
Mounting Support
Plate<br />Rail
Operating time
25...35 ms coil energisation and NC opening<br />30...40 ms between energisation of coil and closing of NO contact<br />30 ms coil de-energisation and NO opening<br />40 ms coil de-energisation and NC opening
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1<br />B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability
10 Mcycles
Electrical durability
0.16 Mcycles 20 A AC-1 <= 690 V
Height
2.3 in (58 mm)
Width
1.8 in (45 mm)
Depth
2.2 in (57 mm)
Net Weight
0.496 lb(US) (0.225 kg)
Product Certifications
CB Scheme<br />CCC<br />UL<br />CSA<br />EAC<br />CE<br />UKCA
Ambient Air Temperature for Storage
-58…176 °F (-50…80 °C)
Operating altitude
6561.68 ft (2000 m) without derating
Fire resistance
1562 °F (850 °C) IEC 60695-2-1
Flame retardance
Class C2 conforming to NF F 16-101<br />Class C2 conforming to NF F 16-102<br />V1 conforming to UL 94

Specifications may be subject to change without notice

Still deciding on LC7K09004M7TQ?

Our engineers can confirm stock, price, and lead time for this schneider part.

Get a no-obligation quote in 1 minute.

Chat with us