Key Features
- 1Optimize high-speed data transfer and processing. 2、Ensure long-lasting operation with durable components. 3、Achieve broad compatibility with various systems and devices. 4、Reduce power consumption while maintaining peak performance. 5、Handle data superiorly with the latest memory technology.
Technical Specifications
Detailed engineering parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Range of Product | Harmony Relay | Series name | Miniature |
| Product or Component Type | Plug-in relay | Device short name | RXM |
| Contacts type and composition | 4 C/O | [Uc] control circuit voltage | 60 V DC |
| [Ithe] conventional enclosed thermal current | 3 A -40…131 °F (-40…55 °C) | Status LED | With |
| Control Type | Lockable test button | Utilisation coefficient | 20 % |
| Shape of pin | Flat | [Ui] rated insulation voltage | 250 V IEC<br />300 V CSA<br />300 V UL |
| [Uimp] rated impulse withstand voltage | 2.5 kV 1.2/50 µs | Contacts material | Gold plated bifurcated silver |
| [Ie] rated operational current | 2 A 28 V DC) NO IEC<br />2 A 250 V AC) NO IEC<br />1 A 28 V DC) NC IEC<br />1 A 250 V AC) NC IEC<br />3 A 28 V DC) UL<br />3 A 277 V AC) UL | Maximum switching voltage | 250 V IEC |
| resistive rated load | 3 A 250 V AC<br />3 A 28 V DC | Maximum switching capacity | 750 VA/84 W |
| Minimum switching capacity | 15 mW 3 mA, 5 V | Operating rate | <= 1200 cycles/hour under load<br /><= 18000 cycles/hour no-load |
| Mechanical durability | 10000000 cycles | Electrical durability | 100000 cycles resistive depending on mounting position and working environment |
| average coil consumption | 0.9 W | Drop-out voltage threshold | >= 0.1 Uc |
| operate time | 20 ms | release time | 20 ms |
| average coil resistance | 4000 Ohm 20 °C +/- 10 % | Rated operational voltage limits | 48...66 V DC |
| Protection category | RT I | Operating position | Any position |
| Net Weight | 0.082 lb(US) (0.037 kg) | Device presentation | Complete product |
| Dielectric strength | 1300 V AC between contacts with micro disconnection<br />2000 V AC between coil and contact<br />2000 V AC between poles | Product Certifications | UL<br />Lloyd's<br />CE<br />CSA<br />GOST<br />IECEE CB Scheme |
| Standards | UL 508<br />CSA C22.2 No 14<br />IEC 61810-1 | Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
| Ambient air temperature for operation | -40…131 °F (-40…55 °C) | Vibration resistance | 3 gn +/- 1 mm 10…150 Hz)5 cycles in operation<br />5 gn +/- 1 mm 10…150 Hz)5 cycles not operating |
| IP degree of protection | IP40 conforming to IEC 60529 | Shock resistance | 10 gnin operation<br />30 gnnot operating |
| Pollution degree | 2 |