TM5SDO2DTRFS

Product ID:34173
Updated: 2026/4/4
schneider TM5SDO2DTRFS

Key Features

  • 1Ensure safety with SIL 3 compliance and 500V AC isolation. 2、Power diverse applications with 24V DC and 230V AC compatibility. 3、Drive demanding loads with up to 6A current per channel. 4、Achieve rapid response with ≤50 ms switching time. 5、Simplify integration with a compact, lightweight design.
Product Details
TM5SDO2DTRFS
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Modicon TM5
Product or Component Type
Discrete output module
Discrete output number
2
Discrete output type
Relay
Range Compatibility
PacDrive LMC motion controller
Product Compatibility
PacDrive LMC Pro 2<br />PacDrive LMC Pro<br />PacDrive LMC Eco
Output voltage
24 V DC<br />230 V AC
Output voltage limits
5...230 V AC<br />5...24 V DC
Discrete output function
2 NO
Current per channel
6 A
Color
Red
Response time
<= 50 ms
Protection Type
Reverse polarity protection<br />Without short-circuit protection<br />Without overload protection
Isolation
No insulation between channels<br />500 Vrms AC insulation between channel and bus
Maximum power consumption in W
1.15 W internal<br />0.26 W bus
Maximum power dissipation in W
2.3 W
marking
CE
Safety level
SIL 3 IEC 61508<br />SIL 3 IEC 62061<br />PL = e EN 13849-1
Safety reliability data
MTTFd > 100 years<br />PFD < 1E-5<br />PFH < 1E-9<br />B10d = 780000 DC-1, 24 V, <6 A<br />B10d = 780000 AC-1, 230 V, <6 A<br />B10d = 1960000 AC-15, 230 V, <3 A<br />B10d = 780000 DC-15, 24 V, <5 A
Net Weight
0.223 lb(US) (0.101 kg)
Standards
IEC 61508<br />UL 508<br />EN 13849-1<br />IEC 62061
Product Certifications
cULus
Ambient air temperature for operation
32…122 °F (0…50 °C) vertical installation)<br />32…131 °F (0…55 °C) without derating horizontal installation)<br />32…140 °F (0…60 °C) with derating factor horizontal installation)
Ambient Air Temperature for Storage
-13…158 °F (-25…70 °C)
Relative Humidity
5…95 % without condensation
IP degree of protection
IP20IEC 61131-2
Pollution degree
2 IEC 60664
Operating altitude
0...6561.68 ft (0...2000 m)
Storage altitude
0.0000000000…9842.5 ft (0…3000 m)
Vibration resistance
1 gn 8.4…150 Hz DIN rail<br />3.5 mm 5…8.4 Hz DIN rail
Shock resistance
15 gn 11 ms
Electromagnetic compatibility
Electrostatic discharge immunity test, 4 kV on contact IEC 61000-4-2<br />Electrostatic discharge immunity test, 8 kV in air IEC 61000-4-2<br />Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz IEC 61000-4-3<br />Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz IEC 61000-4-3<br />Electrical fast transient/burst immunity test, 1 kV I/O IEC 61000-4-4<br />Electrical fast transient/burst immunity test, 1 kV shielded cable IEC 61000-4-4<br />Electrical fast transient/burst immunity test, 2 kV power lines IEC 61000-4-4<br />1.2/50 µs shock waves immunity test, 0.5 kV differential mode IEC 61000-4-5<br />1.2/50 µs shock waves immunity test, 1 kV common mode IEC 61000-4-5<br />Conducted RF disturbances IEC 61000-4-6<br />Conducted and radiated emissions CISPR 11

Specifications may be subject to change without notice