TM5SDO2S

Product ID:34175
Updated: 2026/4/4
schneider TM5SDO2S

Key Features

  • 1Utilize robust components for consistent performance in harsh environments. 2、Integrate seamlessly with Modicon LMC058/M258 and PacDrive motion controllers. 3、Operate on 100-240 VAC for versatile industrial application. 4、Install easily into DIN rail systems with a compact 3-wire design. 5、Meet international safety standards including CSA and IEC.
Product Details
TM5SDO2S
schneider

Technical Specifications

Detailed engineering parameters

ParameterValueParameterValue
Range of Product
Modicon TM5
Product or Component Type
Discrete output module
Discrete output number
2
Discrete output type
Relay
Range Compatibility
Modicon M258<br />Modicon LMC058<br />PacDrive LMC motion controller
Product Compatibility
Motion controller<br />PacDrive LMC Pro 2<br />PacDrive LMC Eco<br />PacDrive LMC Pro<br />Logic controller
Output voltage
100...240 V AC
Current per channel
1 A
Color
Black
Electrical connection
3 wires
marking
CE
Standards
CSA C22.2 No 142<br />IEC 61131-2<br />CSA C22.2 No 213<br />UL 508
Product Certifications
CSA<br />GOST-R<br />cULus<br />C-tick
Ambient air temperature for operation
14…131 °F (-10…55 °C) without derating horizontal installation)<br />14…140 °F (-10…60 °C) with derating factor horizontal installation)<br />14…122 °F (-10…50 °C) vertical installation)
Ambient Air Temperature for Storage
-40…158 °F (-40…70 °C)
Relative Humidity
5…95 % without condensation
IP degree of protection
IP20IEC 61131-2
Pollution degree
2 IEC 60664
Operating altitude
0...6561.68 ft (0...2000 m)
Storage altitude
0.0000000000…9842.5 ft (0…3000 m)
Vibration resistance
1 gn 8.4…150 Hz DIN rail<br />3.5 mm 5…8.4 Hz DIN rail
Shock resistance
15 gn 11 ms
Electromagnetic compatibility
Electrostatic discharge immunity test, 4 kV on contact IEC 61000-4-2<br />Electrostatic discharge immunity test, 8 kV in air IEC 61000-4-2<br />Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz IEC 61000-4-3<br />Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz IEC 61000-4-3<br />Electrical fast transient/burst immunity test, 1 kV I/O IEC 61000-4-4<br />Electrical fast transient/burst immunity test, 1 kV shielded cable IEC 61000-4-4<br />Electrical fast transient/burst immunity test, 2 kV power lines IEC 61000-4-4<br />1.2/50 µs shock waves immunity test, 0.5 kV differential mode IEC 61000-4-5<br />1.2/50 µs shock waves immunity test, 1 kV common mode IEC 61000-4-5<br />Conducted RF disturbances IEC 61000-4-6<br />Conducted and radiated emissions CISPR 11

Specifications may be subject to change without notice